– 78 –

FIRST TEST REPORT TIME

*83
00-07 = day that the first test report shall be transmitted
00-23 hours/00-59 min. = time that the first test report shall be
transmitted
00 = immediately upon exiting programme mode
00 entry in the day location will cause the report to be sent at the next
occurrence of the time that is set.
Day 01=Monday. See fields *81 & *82 for assigning the Test Report code.
INTERMITTENT SENSOR SUPPRESSION
*84
01-15 = number of messages (alarms or troubles) sent for a specific
channel in an armed period (Intermittent Sensor Suppression)
00
= all alarm or trouble codes are reported.
ENABLE DIALLER REPORTS
*85
FOR PANICS & DURESS
1 = enable panic/duress reporting for each location
0 = disable panic/duress reporting
REPORT/LOG ZONE TYPE 23
*86
1 = faults of zone type 23 zones communicated in Contact ID format and
logged in the event log.
0 = zone type 23 zone faults are not to be communicated or event logged
ENTRY WARNING
*87
1 = slow beeps that continue for the entire entry delay period
0 = 3 short beeps
BURG. ALARM COMM. DELAY
*88
1 = 16-second delay (no delay on 24-hour reports)
0 = no delay on burglary alarm communication

RESTORE REPORT TIMING

*89
0 = instant restore report as zone restores
1 = reporting after siren timeout if zone restored
2 = restore report when system is subsequently disarmed
SECONDARY SUBSCRIBER ACCT #
*90
(partition-specific)
00-09; B-F (11-15) = enter the 3 or 4 digit number (depending on report
format) for the secondary subscriber account, . Each number requires a 2-
digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit
number is to be used, only enter data in the first 6 locations, leaving the
last two unfilled. Default=15 15 15 15. Erase the field by entering *90*.
NOTE: This field must be programmed if a secondary phone number is
used (field *34). This account number can be the same as the primary
account number.
CONTACT ID REPORTING IN ASCII THROUGH
1*00
PRINTER PORT
1= Yes
0= No, event log usage
ASCII CONTACT ID REPORTING WITH OR WITHOUT ACK
1*01
1= ACK not required
0= ACK required
ASCII CONTACT ID BAUD RATE
1*02
0= 1200
1= 2400
2=
(partition-specific)
(partition-specific)
(partition-specific)
|
|
(partition-specific) [03]
[0]
995 996 999 Duress
[0]
[1]
[0]
[0]
|
|
|
[15
15
15
15]
[0]
[0]
[0]
|
|
|
4800