House Id Sniffer Mode - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

Installing the
5800TM Module
5800TM Wiring
Connections
House ID Sniffer
Mode
–32–
MOUNTING
HOLES
TO
RELEASE
CIRCUIT
BOARD,
REMOVE
SCREWS
ON
1 2 3 4 5 6 7 8
NOT USED
5882EU ADDRESS SETTINGS
SWITCH
(" " means "OFF")
POSITION
0
1
2
3
4
5
ON
ON
ON
4
ON
3
ON
Figure 14b: 5882EU Wireless Transceiver (cover removed)
Take note of the address you select for the wireless receiver as this address must be
enabled in the system's Device Programming mode.
Installation of this module is necessary only if you are using one or more 5827BD
Wireless Bi-directional keypads.
The 5800TM must be located between 0.3m and 0.6m from the 4281 or 5881
receiver's antennas.
cabinet. Mount the unit using its accompanying mounting bracket.
Connect the 5800TM to the control panel's keypad connection terminals, using
the supplied connector with flying leads, as follows:
WIRE
RED (+12VDC)
BLACK (Ground)
GREEN (Data to Control)
YELLOW (Data from Control)
BLUE: Not Used
Cut the red jumper for address setting 28; cut the white jumper for address 29;
cut both jumpers for address 30.
This address must be enabled as an alpha keypad in the control's Device
Programming mode and then assigned to a partition.
For additional information, refer to the 5800TM's instructions.
This mode applies only to 5700 series systems, or if you are using a wireless
keypad (5827/5827BD) in a 5800 series system.
5700 series receivers respond only to transmitters set to the same House ID (01-
31) that is programmed into the control panel. This prevents system interference
from transmitters in other nearby systems. Use the House ID Sniffer Mode to
ANTENNAS.
INSERT IN
RIGHT-HAND
TERMINALS
CPU FAIL LED
PLUG
RF ACTIVITY
&
LED
SOCKET
DIP
1 2 3 4 5 6 7 8
POSITION 7: ON selects "quiet" mode where the 5882EU
only sends signals upon alarms or if it receives a signal from
NOT USED
a 5839EU keypad. OFF selects normal mode. Use OFF position
if 5839EU is plugged into an external power source or if a
5840EU siren is being used.
5
6
7
ON
ON
POSITION 6: ON selects addressable mode for use with the
ON
ON
4140XMPT2 / VISTA-120, wherein positions 3-5 set the address.
ON
ON
ON
OFF selects non-addressable mode for use with the 4111XM /
VISTA-25, where the settings of positions 3-5 must be OFF.
The 5800TM must not be installed within the control
TERMINAL ON CONTROL
Terminal 6
Terminal 7
Terminal 8
Terminal 9
TO CONTROL'S
YELLOW
}
REMOTE KEYPAD
RED
CONNECTION
POINTS.
BLACK
USE MAX 67M OF
GREEN
0.8MM WIRE OR
168M OF 1MM WIRE.
WIRING
OPENING
KNOCKOUT
AREA FOR
SURFACE
WIRING
REED TAMPER