General Description - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

NOTE: This manual describes features of Vista-120 with software revision "WAVIS120-14." New
features included in this version are indicated by margin lines.
The VISTA-120 is an 8-Partition alarm control panel that supports up to 128 zones using basic wired, polling
loop, and wireless zones.
automating system functions. The major system features are outlined below.
New Features
This version of the VISTA-120 has enhanced features not found in the prior version. These enhancements
include the following:
• Support for unique features of 5800EU supervised
wireless system, including RF jamming detection
and processing, activation of RF wireless siren,
and more frequent supervision.
• Expansion of the number of programmable
outputs from 32 relays (on 4204s) to 96 via polling
loop support of up to 64 4101SN programmable
relays and/or open collector outputs on 4208UXM
Mk3 zone expander modules (4 per module).
• Integration of VISTA-120 with PassPoint Access
Control System so that VISTA-120 status/users
can influence/control PassPoint ACS and unused
PassPoint zones can become part of VISTA-120's
complement of protection zones.
• Self actuating siren/bell support
• Support for Final Contact Set arming mode
• Optional restrictions on downloading functions
permitted when system is armed
• Optional use of zone 9 for Telephone Line Monitor
output processing
• Optional restrictions on various keypad displays
during the armed or disarmed modes for higher
security applications.
• Support for faster (8x) processing of polling loop
sensor zone faults for serial number address
devices
• Expansion of the number of zone lists for use with
programmable outputs from 8 to 15
• Optional limit on the number of zones that may be
bypassed per partition
• Optional use of the printer port to transmit ASCII
Contact ID messages to computer systems,
communication networks, and other
communication media
• Provision of a Contact ID data packet on the
keypad bus for interface to communication
networks and other communication media
–2–
SECTION 1

General Description

In addition, the control offers relay control and scheduling capabilities for
• Support for future intelligent polling loop motion
sensors that will send more data on the bus
• Support for Robofone version of Contact ID format
• Optional communication of verified intrusion
alarm reports and provision of a unique output
• Support for the processing of high and low
sensitivity maintenance signals from intelligent
polling loop addressable smoke detectors
• Support for special Scandinavian required
software features to permit insurance regulatory
approvals
• Support for special telecom hardware/software
capabilities for PTT approvals in Finland, Norway,
Sweden, Netherlands, Belgium, France, and
Australia.
Basic Wired Zones
Provides 9 basic wired zones:
• EOLR
supervision
supporting N.O. or N.C. sensors
• Individually assignable to one of 8 partitions
• Up to 16 2-wire smoke detectors on zone 1
• 4-wire smoke or heat detectors on zones 1-8 (not
permitted for UL installations)
• Up to 50 2-wire latching glassbreak detectors on
zone 8
Polling Loop Expansion:
Supports up to 119 additional wired zones using a
built-in polling (multiplex) loop interface. Current
drain can total up to 128mA.
have the following characteristics:
• Must use RPM (Remote Point Module) devices
• Supervised by control panel
• Individually assignable to one of 8 partitions
(optional
for
zones
Polling loop zones
2-8)