This section provides the following information:
General
Information
SECTION 13
Voltage Triggers
• General information about the voltage triggers
• Ground Start trigger setup
• Open/Close trigger setup
• Keyswitch setup
• Remote keypad sounder setup
• Long Range Radio or other transmission media triggering
Connector J7, located on the right hand side of the main PCB, provides 4 trigger
outputs. These outputs may be configured in a number of ways, depending upon
the requirements of the installation. They may be used for:
• Operating the 675 Ground Start Module
• Operating the 4146 Keyswitch LEDs
• Operating a remote piezo sounder that imitates the keypad sounder
• Triggering auxiliary alarm signaling equipment (such as long range radio
transmitters)
• Operating an Audio Alarm Verification (AAV) module (see previous section on
AUDIO ALARM VERIFICATION.
These output triggers can be enabled by partition via programming field 2*20.
The pin assignments of this connector are shown below. Use only the 4142TR
9-wire cable (available as an option) for making connections to this connector.
Output 1:
Operates, by default, as a trigger for the 675 ground start module.
output may optionally be programmed to operate as an open/close trigger, a
remote keypad sounder output, or an AAV module output (programmed in
data field 1*46). Only one of these options may be used at a time.
Output 1 Rating:
Outputs 2 & 4:
Operates, by default, as Fire and Silent Panic/Duress triggers, respectively.
These triggers may optionally be programmed to act as Arm and Ready status
indicators when it is desired to use the 4146 keyswitch (programmed in data
field *15). Output 2 can alternatively be programme selected to be a CPU fail
output.
Output 2 & 4 Rating:
Output 3:
Operates as a Burglary/Audible Panic trigger. There are no other options for
this output.
Output 3 Rating:
1
2
3
4
N/U
OUT 1: GROUND START, OPEN/CLOSE, REMOTE SOUNDER, OR AAV
OUT 2: FIRE OR KEYSWITCH ARMED LED OR CPU FAIL
OUT 3: BURGLARY/AUDIBLE PANIC/AUXILIARY
OUT 4: SILENT PANIC/DURESS OR KEYSWITCH READY LED
When Activated: 10 - 13.8 VDC through 4K ohms
When De-activated: 100 ohms to ground
When Activated: 10 - 13.8 VDC through 5K ohms
When De-activated: 1K ohms to ground
When Activated: 10-13VDC through 5K ohms
When De-activated: 1K ohms to ground
5
6
7
8
9
J7 CONNECTOR