ADEMCO VISTA-120 Installation And Setup Manual page 11

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

Wireless Expansion:
Supports up to 63 wireless zones using 4281 type RF
Receiver or 128 wireless zones using 5881/5882EU
type RF Receiver (less if using basic wired and/or
polling loop zones). Wireless zones have the
following characteristics:
• Supervised by control panel for check-in signals
(except certain non-supervised transmitters)
• Supervised for low battery condition
• Cover
removal
5800/5800EU series supervised transmitters
• Wall removal tamper protection for 5800EU
series supervised transmitters
• Individually assignable to one of 8 partitions
For specific information regarding number
of wireless zones supported by each RF
receiver, see the section on Wireless
Expansion later in this manual.
Pass Point Access Control System (ACS)
If the PassPoint ACS has uncommitted zones, up to
32 of these zones can be used as if they were basic
wired zones, as long as they are within VISTA-120's
total capacity of 128 protection zones.
Supervisory Zones
Provides additional zones for supervision of the
following:
J7 Trigger Outputs
RF Receivers
Polling Loop
Peripheral Devices
Supports up to 32 addressable devices, which can be
any combination of 6139/5839EU keypads, RF
receivers (4281/5881/5882EU), relay modules (4204),
and the 4285 VIP module. Peripheral Devices have
the following characteristics:
• Terminated at the Keypad Port terminals on the
control panel (except for wireless 5839EU)
• Each
device
set to
(physically) according to the device's instructions
• Each device enabled in the system using the
Device Programming Mode
Optional Vista Interactive Phone Module
Supports the Ademco 4285 VIP Module, which
permits access to the security system by telephone
to do the following:
• Obtain system status information
• Arm and disarm security system
• Control relays and/or Powerline Carrier devices
tamper
protection
Zone 973
Zones 988, 990
Zone 997
an
individual
address
8 Partitions
Provides the ability to control 8 separate areas
independently, each functioning as if it had its own
separate control. Partitioning features include:
• Up to 3 "Common Area" partitions, which arm
automatically when the last partition (1-8) that
shares the common area is armed and disarms
when the first partition (1-8) that shares the
common area is disarmed
• A Master Partition (9) to which keypads may be
for
assigned to view the status of all 8 partitions at
the same time
• Keypads assignable to one of 8 partitions or to
Master Partition 9 to view system status
• Ability to assign Relays/Powerline Carrier devices
to one or all 8 partitions
• Certain system options selectable for each
partition,
such
Subscriber Account Number
User Codes
Accommodates 150 user codes, all of which can
operate any or all partitions. Each user, if assigned
to more than one partition, retains the same user
number across all partitions, and will only utilise
one user "slot" in the system. Certain characteristics
must be assigned to each user code as follows:
• Authority level for each partition (Master,
Manager, or several other Operator levels)
• Opening/Closing central station reporting option
• What partitions the code can operate
• Global arming capability (arm and disarm all
partitions the code has access to in one command)
• Use of a wireless transmitter to arm and disarm
the system (wireless transmitter must first be
"enrolled" into the system
Keypad Panic Keys
Accommodates three keypad panic keys: 1+
+# (B), and 3+# (C).
• Designated as zones 995 (1+ ), 996 (3+#), and
999 ( +#)
• Activated by wired and wireless keypads
• Activated and reported separately by partition,
distinguished
Partition No. if Contact ID reporting is used)
Keypad Macros
Accommodates up to 4 keypad macro commands per
partition (each macro is a series of keypad
commands), which can be assigned to the A, B, C
and D keys on each partition's keypads.
This means, for example, that by pressing the "D"
key,
the system can be programmed to log onto
another partition, bypass zones 2 and 3, and arm
that partition in the AWAY mode (explained in
detail later in this manual). Each macro can be up
to 32 characters in length.
as
Entry/Exit
Delay
by
Subscriber
Acct.
and
(A),
No.
(or
– 3 –

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents