RANDOMISE AC MAINS LOSS REPORT

*19
1 = randomise AC loss reporting between 30-60 minutes after an actual
AC loss
0 = normal AC loss reporting (about 2 minutes after actual AC loss)
Selecting this option helps prevent an overload of AC loss messages at
the central station during a community blackout.
TELEPHONE MODULE PHONE CODE
*20
01-09 = first digit
11 (for
) or 12 (for #) = second digit
To disable the voice module, enter 00 for the 1st digit and enter 11 for the
2nd digit of the code (disable code = 00,11).
This is the 2-digit phone code used to access the system via the 4285
telephone module.
PREVENT FIRE TIME-OUT
*21
1 = disable (no timeout) the alarm sounder duration for any zone
designated as a fire zone, regardless of partition, so that fire
sounding continues until the system is reset
0 = the normal burglary alarm sounder duration (programmed in
partition-specific field *13) should apply to fire alarms.
KEYPAD PANIC ENABLE (partition-specific)
*22
1 = enable the appropriate keypad panics used in this partition
0 = disable keypad panics
MULTIPLE ALARMS (partition-specific)
*23
1 = enable multiple alarms
0 = disable multiple alarms
Determines whether or not more than one alarm can be sounded in a
given zone during an armed period. Note that multiple alarm soundings
will not occur more frequently than allowed by the programmed alarm
sounder duration. This selection applies to local sounding and has no
impact on the number of communication messages transmitted. Refer to
Intermittent Sensor Suppression for limiting communication messages.

IGNORE EXPANSION ZONE TAMPER

*24
1 = disable (ignore) tamper
0 = tamper detection is desired (ANPI requirement)
Only applicable to certain polling loop sensors with tamper switches or
5800 series transmitters. This option is used to disable tamper detection
on these devices.
BURGLARY TRIGGER FOR RESPONSE TYPE 8
*25
1 = allow optional triggering of the voltage output on pin 7 of the J7
header to include zone response type 8 (24hr. auxiliary).
0 = only burglary and audible panic alarms (zone type 7) will trigger pin
7.
INTELLIGENT TEST REPORTING
*26
1 = no test report sent if any other type of report was sent since the last
test report
0 = test reports are to be sent at the set intervals, regardless of whether
or not other reports have been sent
TEST REPORT INTERVAL
*27
001-999 = test reporting interval in hours
000 = no test reporting is desired.
If a test report is desired, enter a test code in fields *81 & *82, location 7.