ADEMCO VISTA-120 Installation And Setup Manual page 119

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

Extend Closing
• A user can manually extend the arm (closing) time window
Window
Force Arm
• The Enable Force Arm option causes the panel to attempt to
Auto Disarming
• The system can automatically disarm at the end of a pre-
Disarm Delay
• Auto-disarm delay provides a delay before Auto disarming.
Restrict
• This option, set in partition-specific field 2*10, allows
Disarming
Exception
• This option allows a means of reporting openings and
Reports
• The
Time Driven
• By using time windows, the system can automatically
Events
• The system can perform the same actions on a daily basis, or
• The system also provides up to 20 "timers" available to the
Limitation of
• A user's access can be limited to a certain time period,
Access By Time
by 1 or 2 hours. This is done by entering a keypad command
(security code + #82), which then prompts the user to enter
the desired extension time of 1 or 2 hours (refer to the
SYSTEM
OPERATION
Instructions). This feature is useful if a user must stay on
the premises later than usual.
bypass any faulted zones prior to auto-arming (panel will
perform a force-arm). This option is set in partition-specific
programme field 2*08.
determined time window, if the system has not been
disarmed manually. The disarming time can be delayed by
using the auto disarm delay feature. In addition, the system
can restrict disarming to a pre-determined time.
This delay is added to the end of the disarm window. The
delay is set in 4 minute increments, up to 56 minutes, in
partition-specific programme field 2*07.
disarming by operator level users only during the disarm
time window, the arming window (in case user needs to
reenter premises after arming), or when the system is in
alarm.
closings by exception (sent only if event occurs outside of the
predetermined opening/closing time windows).
system
sends
opening/closing occurs by the end of the corresponding
window.
activate and de-activate relays and/or power line carrier
(X-10) devices at pre-determined times to turn lights or other
devices on and off.:
can be made to perform an action only once (i.e., turn on the
porch light this Wednesday at 8:00pm).
end user for the purpose of activating output devices at
preset times and on preset days.
during
which he can perform system functions. Outside this time,
that user's code will be inactive. The system provides up to 8
Access Schedules, each consisting of two Time Windows (one
for opening, one for closing) for each day of the week and two
time windows for holidays. The access schedules are
programmed via #80 Menu Mode, and enabled for a given
user when that user is added to the system. If a user tries to
operate the system outside of the schedule, the alpha keypad
will display "Access Denied."
section
of
the
missed
open/close
reports
Installation
if
no
— 111 —