Type 00: Zone Not Used
Programme a zone with this zone type if the zone is
not used.
Type 01: Entry/Exit #1 Burglary.
This zone type provides entry delay whenever the
zone is faulted if the control is armed in the Away or
Stay modes. When the panel is armed in the Instant
or Maximum modes, no entry delay is provided. Exit
delay begins whenever the control is armed,
regardless of the arming mode selected. These
delays are programmable. This zone type is usually
assigned to sensors or contacts on doors through
which primary entry and exit will take place.
Type 02: Entry/Exit #2 Burglary
This zone type provides a secondary entry delay
whenever the zone is faulted if the panel is armed in
the Away and Stay modes. When the panel is armed
in the Instant or Maximum modes, no entry delay is
provided. Secondary exit delay begins whenever the
control is armed, regardless of the arming mode
selected. These delays are programmable. This zone
type is usually assigned to sensors or contacts on
doors through which more time is needed to get to
and from the keypad. Delay times for this zone type
must be greater than Zone Type 01. (Ex.: a garage,
loading dock, or basement door)
Type 03: Perimeter Burglary
This zone type gives an instant alarm if the zone is
faulted when the panel is armed in the Away, Stay,
Instant or Maximum modes. This zone type is
usually assigned to all sensors or contacts on seldom
used exterior doors and on windows.
Type 04: Interior, Follower.
This zone type gives a delayed alarm (using the
programmed Entry /Exit time) if the Entry/Exit
zone is faulted first. Otherwise this zone type gives
an instant alarm. This zone type is active when the
panel is armed in the Away or Maximum modes.
Maximum mode eliminates the entry delay. This
zone type is bypassed automatically when the
panel is armed in the Stay or Instant modes.
This zone type is usually assigned to a zone covering
an area such as a foyer, lobby, or hallway through
which one must pass upon entry or exit(After
faulting the entry/exit zone to reach the keypad to
disarm the system.)
designed to provide an instant alarm if the
entry/exit zone is not violated first, it will protect an
area in the event an intruder hides on the premises
prior to the system being armed, or gains access to
the premises through an unprotected area.

ZONE RESPONSE TYPE DEFINITIONS

.
Since this zone type is
Type 05: Trouble by Day/Alarm by Night
This zone type will give an instant alarm if faulted
when armed in the Away, Stay, Instant or
Maximum (night) modes. During the disarmed state
(day), the system will provide a latched trouble
sounding from the keypad (and a central station
report, if desired). This zone type is usually
assigned to a zone which contains tamper switches,
or to a zone covering a "sensitive" area such as a
stock room, drug supply room, etc. This zone type
can also be used on a sensor or contact in an area
where immediate notification of an entry is desired.
There are programming options to prohibit bypass
of this zone type except by installer and to prohibit
restoration of the system (or partition) to the
disarmed, ready to arm state subsequent to a
trouble or alarm condition related to this zone type,
except by the installer.
Type 06: 24-hour Silent Alarm.
This zone type sends a report to the Central Station
but provides no keypad display or sounding. This
zone type is usually assigned to a zone containing
an Emergency button.
Type 07: 24-hour Audible Alarm.
This zone type sends a report to the Central Station,
and provides an alarm sound at the keypad, and an
audible external alarm. This zone type is usually
assigned to a zone that has an Emergency button.
Type 08: 24-hour Auxiliary Alarm.
This zone type sends a report to Central Station and
provides an alarm sound at the keypad. (No
bell/siren output is provided). This zone type is
usually assigned to a zone containing a button for
use in personal emergencies, or to a zone containing
monitoring
devices
temperature sensors, etc.
Type 09: Supervised Fire. (No Verification)
This zone type provides a fire alarm on short circuit
and a trouble condition on open circuit. The
bell/siren output will pulse when this zone type is
shorted. This zone type is always active and cannot
be bypassed. This zone type can be assigned to
any wired zone except zone 9, and can be
assigned to certain wireless system zones.
such
as
water
sensors,
.