Specifications - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

VISTA-120 CONTROL
Physical:
Electrical:
VOLTAGE INPUT:
ALARM SOUNDER OUTPUT: 10VDC-13.8VDC (10.7VAC-14.5VAC for Vista-120FR), 2.8 amps
AUXILIARY POWER OUTPUT: 9.6VDC-13.8VDC, 750mA max.
BACK-UP BATTERY:
STANDBY:
CIRCUIT PROTECTORS:
DIGITAL COMMUNICATOR
FORMATS SUPPORTED:
ADEMCO HIGH SPEED
ADEMCO 4+2 EXPRESS
ADEMCO LOW SPEED
ADEMCO CONTACT ID
SESCOA
RADIONICS LOW SPEED
LINE SEIZE: Double Pole
6139 Remote Keypad
Physical:
Width:
159mm
Height:
121mm
Depth:
32mm
Electrical:
Voltage Input: 12VDC
Current Drain: 100 mA
Interface Wiring:
RED: 12VDC input (+) auxiliary power
BLUE: Not Used
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection from supplemental power supply.
– 162 –

SPECIFICATIONS

318mm Wide X 368mm High X 76mm Deep
In 110 volt AC mains systems, from Ademco No. 1361 Plug-In
Transformer (use 1361CN in Canada) or 4300 transformer (for X-
10 installations) rated 16.5VAC, 40 VA or XF10 transformer (for
220VAC, 50Hz X-10 installations)
max.; 750mA less aux. current drain
12VDC, 4AH or 7AH gel cell. No. 467 (12V, 4AH) or 712BNP
(12V, 7AH) recommended.
4 hours min. with 750 mA aux. load using 7 AH battery.
PTC circuit breakers are used on battery input to protect against
reverse battery connections and on alarm sounder output to
protect against wiring faults (Shorts).
A solid state circuit breaker is used on auxiliary power output to
protect against wiring faults (shorts).

Hide quick links: