NOTE: Use of more
than 50 DIP switch
devices can greatly
impact the panel's
ability to respond to a
change in status in a
timely manner.
DIP switch devices
that affect response
time include:
4278EX, 4275EX,
4190WH, 7500, 9500
–28–

Compatible Polling Loop Devices

4208U
8-Zone Expander
4208UXM3
4209U
Group Zoning Mod.
(4-Zone Expander)
4190WH
2 -Zone Expander
4190SN
2-Zone Expander
4278EX
Quad PIR
4278EX-SN
4275EX
Dual PIR
4275EX-SN
• Supports up to 8 zones via the polling loop.
• Must use serial number enrollment mode.
• The first two zones can be either normal or
fast response (DIP switch selectable).
• All zones are EOLR supervised (10k ohms),
provided with the 4208.
• The 4208UXM3 has 4 programmable O.C.
output triggers and can be configured for double
balanced zones for non-fire applications.
• Supports up to 4 zones via polling loop.
• Must use serial number enrollment mode.
• 4 supervised zones or 2 supervised zones in
"group" mode (2 zones grouped as 1 zone)
• Supports 2-wire smoke det. loops, 16 per zone if 4
zones used or 32 per zone if 2 zones used.
• All zones are EOLR supervised (2k ohms),
provided with the 4209U.
• Supports up to 2 zones via the polling loop.
• DIP switch programmable (128 addresses).
NOTE: Use of 4190SN is preferred, whenever
possible, for improved system timing.
• Tamper protected
• The left zone can be EOLR supervised, can accept
either open or closed circuit sensors, and can be
set for fast response.
• The right zone is unsupervised and can
accept closed circuit sensors only.
• Supports up to 2 zones via the polling loop.
• Tamper protected
• The left zone can be EOLR supervised, can accept
either open or closed circuit sensors, and can be
set for fast response.
• The right zone is unsupervised and can accept
closed circuit sensors only.
• Quad element mirror optics PIR with
built-in RPM
• Serial number ID "enrolled" by control ("SN")
NOTE: Use of 4278EX-SN is preferred, whenever
possible, for improved system timing.
• 4278EX DIP switch programmable; 64 addresses.
• Tamper protected.
• Includes mirrors for both wide angle and
curtain/long range applications.
• Features an auxiliary sensor loop that is
non-supervised and can accept closed circuit
sensors only.
• 4278EX can have its walk test LED
enabled/disabled via keypad commandsrouted
over the polling loop
• Dual element PIR with built-in RPM
• Serial number ID "enrolled" by control ("SN")
NOTE: Use of 4275EX-SN is preferred, whenever
possible, for improved system timing.
• 4275EX DIP switch programmable (64 addresses)
• Tamper protected
• Includes mirrors for both wide angle and
curtain/long range applications and can use
the 1875PA Pet Alley mirror.
• Built-in selectable pulse count capability.
• 4275EX can have its walk test LED
enabled/disabled via keypad commands
routed over the polling loop