ADEMCO VISTA-120 Installation And Setup Manual page 175

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

NOTES: 1. Zone 1 may be selected for EOLR supervised
or normally closed (no EOLR) operation via
cut jumper. (Cut red jumper for normally closed
operation. Do not cut for Fire Usage). Zones 2-8
may be selected for either operation via program
field *41.
2.
Zone 1 supports 2-wire smoke detectors.
See Installation Instructions for recommended type
BATTERY
and maximum number of detectors supported.
TABS
Connect to
12VDC, 4AH
or 12VDC, 7AH
1
2
3
4
5
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.8VDC
See
Connect to 24hr.
Installation
120VAC, 60 Hz
Instructions for
or
required
220VAC, 50 Hz
capacity
ADDRESSABLE DEVICES
TRANSFORMER
16.5VAC, 40VA
See Installation Instructions
and for max wire run length.
NOTE:
+
-
BELL
WHEN POWERING UP
THE PANEL, CONNECT TO AC
MAINS BEFORE CONNECTING
+
-
AUXILARY POWER OUTPUT
THE BATTERY.
9.6VDC - 13.8VDC,
750 mA maximum
ALL CIRCUITS ARE
Note: Include current drawn
POWER LIMITED.
by keypads and polling loop
devices when making
SIREN
auxiliary power calculations.
ALARM SOUNDER OUTPUT
10VDC - 13.8VDC 2.8A maximum
(10.7VDC - 14.5VDC for VISTA-120FR)
3.
Zone 7 may be used for remote keyswitch
arming/disarming.
See Installation Instructions for wiring
instructions.
4.
Zone 8 supports 2-wire latching type glass
break detectors.
See Installation Instructions for recommend-
ed type and maximum number of detectors
supported.
Red Jumper
(note 1)
ZONE 2 ZONE 3
6
7
8
9
10
11
12
13
14
ZONE 1
+
+
-
+
-
N.C.
N.C.
Red
Blk
Grn
Yel
REMOTE KEYPADS
Use 6139
N.O.
N.O.
(e.g. 4204, 5881, 5882EU)
2k EOLR
2k EOLR
(note 1)
(note 1)
for max # of keypads
+
-
Fire
Usage
SMOKE
N.C.
Burglary
Usage
2k EOLR
N.O.
(note 1)
ZONE RESISTANCE (Excluding EOLR):
ZONE 1,8: 100 OHMS maximum
2k EOLR
ALL OTHER ZONES: 300 OHMS maximum
(note 1,2)
ZONE RESPONSE TIME:
ZONES 1-8: 350mSec-500mSec
ZONE 9: Programmable for
Fast: 10mSec-15mSec
Normal: 350mSec-500mSec
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.
J7 Header
J8 Header
1. Not Used
1. In 2 (Printer DTR)
2. Ground-
2. Ground
3. Out 1 (Ground Start)
3. In 3 (X - 10 sync)
4. In 4 (X - 10 sync)
4. Ground-
5. Out 2 (fire)
5. Ground
6. Ground-
6. Out 5 (X - 10 data)
7. Out 6 (Printer RXD)
7. Out 3 (burg/aud. panic)
8. Ground
8. Ground
9. Out 4 (silent panic/
9. Ground
duress)
(Refer to Installation Instructions for information concerning Direct Wire
Downloading and printer connections using the 4100SM Serial Module.)
ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8 ZONE 9
15
16
17
18
19
20
21
22
23
+
+
-
N.C.
N.C.
N.O.
N.O.
2k EOLR
2k EOLR
+
-
+
(note 1)
(note 1,3)
+
+
-
GLASS
BREAK
N.C.
N.C.
N.C.
N.C.
N.O.
N.O.
N.C.
N.O.
2k EOLR
2k EOLR
(note 1)
(note 1,4)
(default response)
MAKE CONNECTIONS USING
No. 4142TR CABLE
Optional programming:
Out 1: Open/close or keypad-like sounding
Out 2: Armed LED, Fire, CPU Fail
Out 4: Ready LED
Ratings for Out 1:
Active: 10VDC-13.8VDC through 4k OHMS
1 2 3 4 5 6 7 8 9
Not Active: 100 OHMS to ground
Ratings for out 2-4:
Active: 10VDC-13.8VDC through 5k OHMS
Not Active: 1k OHMS to ground
1 2 3 4 5 6 7 8 9
24
25
26
27
28
29
30
+
-
Handset
Incoming
Connections
Phone Line
EARTH GROUND
Connections
Connect to good earth
ground to maintain immunity
to transients. See Instructions
for proper grounding.
WARNING: TO PREVENT
RISK OF ELECTRICAL
SHOCK, DISCONNECT
4190
RPM
TELCO JACK BEFORE
SERVICING THIS PANEL.
4192SD
SMOKE
4278EX
PIR
Polling loop rating: 128mA
maximum. See Installation
Instructions for maximum
number of devices supported
and maximum wire run length.
J8
J7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents