Time-Driven Event Programming

Action Codes:
01=Relay On
02=Relay Off
03=Relay Close for 2 seconds
04=Relay Close XX minutes
05=Relay Close YY seconds
06=Relay Group On
07=Relay Group Off
08=Relay Group Close for 2 seconds
09=Relay Group Close XX minutes
10=Relay Group Close YY seconds
20=Arm-Stay
21=Arm Away
22=Disarm
23=Force Arm Stay
24=Force Arm Away
40=Enable Open Window by part
41=Enable Close Window by part
– 122 –
The following schedules can be used to activate outputs, bypass zones,
arm/disarm the system, etc. based on a time schedule. Up to 20 events can be
programmed for the system. Time windows must first be defined in order to be
used to trigger events.
If using Time Driven Events to control relays and/or Powerline Carrier
devices, the following menu items must first be programmed using #93
Menu Mode - Relay Programming:
• Enter Relay No. (reference identification number)
• Relay Group (if applicable)
• Restriction
• Relay Type (4204 or X-10)
• House code and Unit code if X-10 devices
• ECP address and specific Relay No. if 4204 relays
After entering Scheduling Menu Mode, press 0 until the Timed Events ? prompt
appears.
Timed Events ?
1 Yes
0 = No
0
TIMED EVENT # ?
01-20, 00=Quit 01
01 ACTION ?
none
00
Enter the partition to which the action
applies. Enter 0 to select all partitions.
Enter a partition number again to
deselect it. Press
The Time Window ? prompt appears.
Enter 1 to programme timed events using relay outputs or
X-10 devices.
Enter the timed event number to be programmed (01-20)
and press the
key. The system will then prompt the
user to enter the desired action to be taken.
Enter 00 at the TIMED EVENT prompt to quit the timed
event menus and display the Quit ? prompt.
Enter 0 at the Quit ? prompt to return
to
the
main
menu
continue programming. Enter 1 to quit
Scheduling Menu Mode.
Enter the action code for the desired action for this event number
from the list at the left. This could be an output command, an
arming command, or any other time-driven event. Press
accept the entry and display the appropriate action specifier
prompt as follows on the next page.
Actions 01-05
Enter the relay number and press
to accept entry. The Time Window ?
prompt appears.
Actions 06-10
Enter the relay group number and
press
to accept entry. The Time
Window ? prompt appears.
Actions 21-24 and 40-41
Quit ?
choices
and
1 = YES 0 = NO
0
01 RELAY # ?
01 RELAY GRP # ?
PART? 12345678
Key 0-8
to accept entry.
to
00
00
X X