Device Programming - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

Device Programming

This menu is used to programme keypads, receivers and relay modules.
From Data Field Programming mode, press #93 to display "ZONE PROG?". Press 0
repeatedly to display "DEVICE PROG?".
DEVICE PROG?
1=YES 0=NO
DEVICE ADDRESS
01-30, 00=QUIT
DEVICE TYPE
01 CONSOLE PART.
01 SOUND OPTION
01 KEYPAD GBL
1=YES 0=NO
03 RF EXPANDER
HOUSE ID
04 MODULE PART.
– 102 –
Press 1 to enter DEVICE PROGRAMMING mode.
The device address identifies the device to the control. Enter the
2-digit device address number to match the device's physical
address setting (01-30). Press
Note: Device Address 04 must be used for the 4285 Voice Module,
if one is utilized. If not, it can be used for another device type.
Select the type of addressable device as follows:
00 = device not used
01 = keypad (6139)
03 = RF receiver (4281/5881/5882)
04 = output relay/trigger module (4204)
05 = telephone module (4285)
Press
If device type 01 was selected, this prompt will appear. Enter the
addressable device's default partition number (01 to maximum
number of partitions programmed for system in field 2*00). This is
the primary partition for which the device is intended to be used.
Enter "9" to make this "Master" keypad for the system. Press
Addressable keypads can be individually programmed to suppress
arm/disarm beeps, entry/exit beeps and chime mode beeps. This
helps prevent unwanted sounds from disturbing users in other
areas of the premises.
Enter a number 00-03 for the keypad sounding suppression options
desired for the keypad as follows:
00 = no suppression.
01 = suppress arm/disarm & entry/exit beeps.
02 =suppress chime mode beeps only.
03 = suppress arm/disarm, entry/exit and chime mode beeps.
The screen will display the next device number to be programmed.
Press 00 +
Press *99 to exit programme mode.
Enter the [Installer Code] + OFF to cancel the system's settling
delay.
If device type 01 was selected, this prompt will appear. Press 1 to
enable this particular keypad to execute global arm/disarm
functions.
If device type 03 is selected, this prompt will appear. Enter the 2-
digit House ID (00-31). This is required for 5700 series systems
00
only, or if using a wireless keypad (5827/5827BD) with a 5800
series system.
If device type 05, telephone module was selected, enter the
partition number 1-8 in which the telephone module is located.
Press
.
Device Address 00 is always set as an alpha keypad assigned to Partition 1 with no
sounder suppression options.
06 = LRR or Contact ID on keypad bus
09 = Vista Gateway
to accept entry.
to exit Menu Mode.
to accept entry.
.

Hide quick links:

Advertisement

Table of Contents
loading