Moving from One
Page of
Programming to
Another
Viewing Data
Fields

Entry Errors

Programming
System-Wide Data
Fields
–66–
Enter the first field number to be programmed (ex. *00, installer's code) and
make the desired entry. When the field is complete, the keypad will normally
"beep" three times and will advance to the next field. If you do not desire to
change the next field, press [ ]and the next field number to be programmed.
press *99 or *98 to exit programme mode
• The data fields are grouped into three levels (referred to as "pages"). The first
page is accessed as soon as programming mode is entered.
• The second and third pages of data fields are indicated at the keypad by a "1"
or "2" respectively in front of the 2-digit field address.
PROGRAM MODE" along with a "100" or "200", depending on which page of
programme fields is accessed, to indicate the higher page of fields.
1. To access the next level of fields, press *94.
2. Then press [ ]+ [XX], where XX=the last two digits of the programme field,
and make the desired entry.
3. To return to the previous page of fields, press *99.
press *94 to move to 2nd page
press *94 to move to 3rd page
To view the contents of a data field, press [#] plus the 2-digit field address.
The field's entries will be displayed, but no changes can be made.
• If an address is improperly entered, the keypad will display FC.
• If a programme entry is improperly entered (for example, a larger number
than that which is permitted), the keypad display will go blank.
• In either of the above cases, simply re-enter
SUMMARY OF DATA FIELD PROGRAMMING COMMANDS
*94
Next page of fields
*99
Previous page of fields or exit programming mode with no installer
lockout
*91
Select partition for programming partition-specific fields
*98
Exit programming mode with installer lock-out
Values for some programming fields are system-wide (global), and some can be
different for each partition (partition-specific). Note that the partition-specific
programming fields are automatically skipped when programming the global
fields. If the system has only 1 partition, the partition-specific fields will not be
automatically skipped. To programme system-wide data fields, do the following:
1. Enter Programme Mode: Installer code + 8 0 0 0.
2. When the programme screen is displayed, press *00 to begin programming the
Installer Code data field.
When you have completed the entry, the keypad sounds three beeps and
automatically displays the next programme field in sequential order.
3. To programme specific data fields out of sequence, press
field address of the field number you want to programme, then make the
required entry.
If the number of digits that you enter in a data field is less than the maximum
permitted (ex. phone number), the keypad displays the last entry and waits.
First Page of Fields
(*00-*90)
press *99 to move back to 1st page
Second Page of Fields
(1*01-1*77)
press *99 to move back to 2nd page
Third Page of Fields
(2*00-2*24)
+ the correct field number.