Type 10 : Interior w/Delay.
This zone type gives entry and exit delays (using the
programmed entry/exit time), if tripped when the
panel is armed in the Away mode. This zone type is
also active during Maximum mode, but no entry
delay is provided (alarms occur immediately if zone
is tripped). This zone type is bypassed when the
panel is armed in the Stay or Instant modes.
Delay begins whenever sensors in this zone are
violated, regardless of whether or not an entry/exit
delay zone was tripped first. If an entry/exit zone is
not tripped first, the entry/exit delay for a type 01
zone is used.
Type 19: 24 Hour Trouble
An open or short on a zone with this zone type
causes a trouble response. No external alarm
sounders are activated.
Type 20: Arm-Stay*
This is a special purpose zone type used with 5800
series wireless pushbuttons or a enroll mode polling
loop device, and which will result in arming the
system in the STAY mode when the zone is
activated.
Type 21: Arm-Away*
This is a special purpose zone type used with 5800
series wireless pushbuttons or a enroll mode polling
loop device, and which will result in arming the
system in the AWAY mode when the zone is
activated.
Type 22: Disarm*
This is a special purpose zone type used with 5800
series wireless pushbuttons or a enroll mode polling
loop device, and which will result in disarming the
system when the zone is activated.
Type 23: No Alarm Response
This zone type can be used on a zone when an
output relay action is desired, but with no
accompanying alarm (ex. lobby door access). There
are
programming
options
communicate zone faults for this zone type.
* Note that these zone types are for use by 5800
series devices or serial numbered polling loop
devices only.
Type 27: Access Point
This zone type can be used on zones that are to
signal to the Ademco Passpoint ACS to request
unlatching of a door lock linked to this zone.
– 70 –
to
event
log
and
Type 28: Main Logic Board
(MLB) Supervision
This zone type assigns a zone to supervise the ACS
MLB. If communication between the MLB and the
Vista Gateway Module (VGM) fails, this zone will be
displayed on the keypad as having a "CHECK"
condition. Also, if this zone fails, all Access Control
System, (ACS) input zones will display "Check".
NOTE FOR PANIC KEYS: Keypad panic zones share
the same zone response type for all 8 partitions, but
panics may be individually enabled for each
partition.
IMPORTANT! FAULT ANNUNCIATION
Polling loop and RF troubles (zones 988, 990 & 997)
will report as trouble conditions only, and as such,
should be assigned zone type 05 if annunciation is
desired.
See SUPERVISION notes in POLLING
LOOP and WIRELESS EXPANSION sections for
more information.
Zone Type Defaults
Following are the zone type defaults for zones on
the VISTA-120:
Zone No.
001
002
003
004
005
006
007
008
009–128
601-632
800–831
988
990
995
996
997
999
Zone Type
09
09
03
03
03
03
03
03
00
05
00
00
00
00
00
19
06