Bypass Enable For Fire Zones; Display Trbl Instead Of Check - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

BYPASS ENABLE FOR FIRE ZONES

1*05
1=
Yes, allow bypass of fire zones
2= No, fire zones cannot be bypassed
SUPPRESS ALL KEYPAD DISPLAYS
1*06
WHEN SYSTEM IS ARMED
1= Yes
0= No

DISPLAY TRBL INSTEAD OF CHECK

1*07
1 = display the letters TRBL instead of CHECK when a zone or system
trouble occurs.
0 = display the letters CHECK when a zone or system trouble occurs.
SUPPRESS USE OF "ARMED" LED ON KEYPADS
1*08
(For countries where Red is only for alarm)
1= Yes
0= No
SUPPRESS KEYPAD ARMING STATUS INDICATIONS
1*09
WHEN SYSTEM IS ARMED
1= Yes
0= No
ALARM DISPLAY LOCK
1*10
1 = the keypad display for alarms will always display the first zone to go
into alarm. Subsequent alarm zones shall only be displayed if the
READY key is pressed.
0 = zones in alarm scroll continuously in numerical order
COMMON AREA 1 PARTITION
1*11
1-8 = common area 1 partition
0
= none
AFFECTS COMMON AREA 1
1*12
1 = this partition affects common area 1. This partition will cause
common area 1 to disarm when this partition disarms.
0 = this partition does not affect common area 1
ARMS COMMON AREA 1
1*13
1 = arming this partition causes the system to attempt to arm the
common area 1 partition automatically. Can only arm common area
1 if all other affecting partitions are armed. To enable this function,
field 1*12 (partition-specific) must also be enabled.
0 = does not apply
COMMON AREA 2 PARTITION
1*14
1-8 = common area 2 partition
0
= none
AFFECTS COMMON AREA 2
1*15
1 = this partition affects common area 2. This partition will cause
common area 2 to disarm when this partition disarms.
0 = this partition does not affect common area 2
ARMS COMMON AREA 1
1*16
1 = arming this partition causes the system to attempt to arm the
common area 2 partition automatically. Can only arm common area
2 if all other affecting partitions are armed. To enable this function,
field 1*12 (partition-specific) must also be enabled.
0 = does not apply
(partition-specific)
(partition-specific)
(partition-specific)
(partition-specific)
[0]
[0]
[1]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
– 79 –