Programming the Keypad
1. Enter the ZONE PROGRAMMING section in the #93 Menu Mode.
2. Programme the zone with a response type 27 (Access Point).
3. Enter the access point number (00-31) of the door and indicate whether this is an entry
or exit keypad.
4. Enter the partition number,
5. Enter the input type as Keypad Input (09)
6. Enter the keypad ecp address.
See the ZONE PROGRAMMING section for a detailed explanation.
Using an RF Transmitter Zone
An RF button type transmitter (5804/5804EU), can be used to provide access to or egress
from up to 4 doors. One button will control one door. Also a button can be used to provide
access or egress due to a panic or duress condition.
An RF transmitter (5816/5816EU) can be used with a remote switch to provide an exit in
case of a fire alarm.
The PIR (5890/5888EU) can be used to provide exit while preventing entry through a door.
The smoke detector (5808/5808EU), can be used to provide egress in emergency situations.
Programming the RF Transmitter
1. Enter the ZONE PROGRAMMING section in the #93 Menu Mode.
2. Programme the zone with a response type 27 (Access Point).
3. Enter the access point number (00-31) of the door.
4. Enter whether RF device is for entry or exit.
5. Enter the partition number
6. Enter the input type supervised RF (03), unsupervised RF (04), or button RF (05).
7. Enter the loop number
8. Enroll the serial number.
See the ZONE PROGRAMMING section for a detailed explanation.
RF buttons and pendants must be assigned to a user number in order to function. See the
USER ACCESS CODES section for the procedure.
Wireless Keypads
The wireless keypads (5827 & 5827BD) can provide another way of entering or exiting the
premise. They function the same as the alpha keypads, except when the code + # 73 is
entered. This entry will momentarily allow access to ALL access points in the partition to
which the keypad is assigned
Programming the Wireless Keypad
1. Enter the partition to which the keypad is assigned in field 1*48.
Using ACS Zone Inputs
If the PassPoint ACS has uncommitted zones, these may be used by the Vista-120 as wired
zones.
Programming the ACS Zone Inputs
1. Enter the ZONE PROGRAMMING section in the #93 Menu Mode.
2. Programme this zone as any other zone and indicate the input type as ACS (10).
3. Enter the PassPoint ACS's zone ID (00-31).
See the ZONE PROGRAMMING section for a detailed explanation.
–62–