Zone List Programming - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

Relay Type
V-PLEX ZONE #
ECP ADDRESS
MODULE
RELAY #
House Code
Unit Code
3. When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.
4. If defining a Zone List, continue to the next procedure in this section. If not, enter 00 +
exiting, enter the [Installer Code] + OFF to cancel the system's settling delay.
5. If supervision of the relay is desired, enter a response type for the relay's corresponding
supervisory zone. This is equal to 6 + 2-digit relay number. For example, if you are
programming relay no. 1, the relay's supervisory zone would be 601. Programme this
zone for response type 19 (24 hr. trouble) or 05 (trouble by day, alarm by night) in #93
Programming Mode.

Zone List Programming

After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO."
prompt, you will be asked to enter a Zone List. If a Zone List number was used to start/stop
a relay, you must define the zones belonging to that list:
Enter Zone LIST
00=QUIT
001 Enter Zn Num.
000=QUIT 000
001 Del Zn LIST?
0=No
001 Delete Zone?
0=No
001 Zn to Delete?
000=QUIT 000
– 106 –
Enter 0 for polling loop trigger or relay.
outputs.
continue.
For polling loop trigger outputs (4208UXM)/4101SN), enter the
protection zone number (010-128) linked to each output, if used. If
not using a protection zone on these modules, enter the relay zone
number (601-696). Be sure to enroll the module's serial number (see
Zone Programming ZONE NUMBER prompt). Press
For relay module (4204) outputs, enter the actual relay module's
address (01-15) as set by its DIP switches.
For 4204 relay outputs, enter the specific relay number on that
module (1-4). Press
For Powerline Carrier devices, enter the numerical equivalent of the
House Code of the device as follows:
A=00
B=01
C=02
D=03
Enter the numerical unit code of the Powerline Carrier device (00-31).
Press
The keypad will display the Start and Stop summary screens again.
Press
at the next two prompts. Then enter *99 to exit programming completely. After
Enter the zone list number 01-15. Enter 00 to quit.
00
Using three-digit entries, enter each zone to be included in this
zone list. Press
zones have been entered, enter 00, then press
Enter 0 to save the zone list entered. Enter 1 to delete that zone
1=Yes
list.
Enter 1 to delete one or more zones in that zone list. Enter 0 if no
1=Yes
changes are necessary. If 1 is entered, the next screen will appear,
otherwise the "Enter Zone List" prompt will reappear.
Enter each zone number to be deleted from the zone list, pressing
after each number.
Enter 2 for Powerline Carrier devices.
to continue.
E=04
I=08
F=05
J=09
G=06
K=10
H=07
L=11
to continue.
to continue.
after each zone number is entered. When all
Enter 1 for 4204 relay
Press
M=12
N=13
O=14
P=15
to
to continue.