Relay Voice Descriptors - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

View Zn LIST
00=QUIT 00
XX ASSIGNED ZONE
000=QUIT 000
Press *99 to exit programme mode or continue to the next procedure in this section to
programme Relay Voice Descriptors. Upon exiting programme mode, enter the [Installer
Code] + OFF to cancel the system's settling delay.

Relay Voice Descriptors

If using the 4285 VIP Module, voice descriptors can be programmed for each of the 96
relays/Powerline Carrier/output trigger devices used in the system. These descriptors will be
announced by the voice module when accessing the relays via the # 70 relay access mode via
telephone.
Each voice descriptor can consist of up to 3 words selected from the relay voice descriptor
vocabulary list (found later in this section).
RLY VOICE DESCR?
0=no 1=yes
ENTER RELAY NO.
00=QUIT
01 ENTER DESC
d1
01 ENTER DESC
d2
01 ENTER DESC d3
This will appear if 00 is pressed at the ENTER ZONE LIST prompt.
Enter the zone list number that you wish to view. Press
continue.
Press
quit.
The index numbers from this vocabulary list are to be used for relay voice descriptors
only. For normal system voice annunciation (eg. alarms, troubles, status), use the
highlighted words in the alpha vocabulary list found in the alpha programming section.
To enter relay voice descriptors, do the following:
1. From data field programming mode, press #93 to display the "ZONE PROG?"
prompt.
2. Press 0 (NO) to each menu option until the "RLY VOICE DESCR?" prompt is
displayed. Follow the instructions below. While in this mode, press
advance to next screen. Press #
Press 1 to programme voice descriptors for relays.
Enter the 2-digit relay/X-10 module/trigger number (01-96) for the
relay desired, or enter 00 to quit relay voice descriptor programming
01
mode. Press
From the relay voice descriptor vocabulary list, enter the 3-digit
index number for the first word of the relay descriptor phrase. Press
.
From the relay voice descriptor vocabulary list, enter the 3-digit
index number for the second word of the relay descriptor phrase. If
second word is not desired, press 000. Press
From the relay voice descriptor vocabulary list, enter the 3-digit
index number for the third word of the relay descriptor phrase. If
third word is not desired, press 000. Press
The ENTER RELAY NO. prompt appears. Enter the next relay to
be programmed. When all output devices have been programmed,
enter 00 to quit.
Enter *99 to exit programme mode.
Enter the [Installer Code] + OFF to cancel the system's settling
delay.
to scroll through all zones in that list. Enter 00 +
to backup to previous screen.
.
to
to
to
.
to accept entry.