Level 0: Installer (User 1)

Open/Close Reporting

Level 1: Master Codes
Level 2: Manager Codes
• Programmed in field *00 (default=4-1-4-0). Installer open/close reporting is
selected in field *39.
• Can perform all system functions (arm, disarm, bypass, etc.), but cannot
disarm if armed by another code (or by Quick Arm).
• Can add, delete, or change all other authority level codes, and can select
open/close reports for any user.
• Is the only code that can enter programme mode, but even this can be
prevented by exiting programme mode using *98. (The only way to access
Programming mode if this done is by powering down the system, powering up
again, and then pressing both the * and # keys at the same time within 30
seconds of power up.)
• Must programme at least one master code during initial installation. Master
codes are codes intended for use by the primary user(s ) of the system.
Note: When adding a user, the system will only prompt for Open/Close reporting
capability if the user is being added by the Installer. When a Master or Manager
adds a new user, the new user's Open/Close reporting enable will be the same as
that of the Master or Manager adding the user.
required to be selectable by the Master or Manager, the Installer should assign
two Master or Manager user codes: one with Open/Close reporting enabled, and
one without.
Note that Open/Close reporting of Quick Arm is enabled if User 2 is enabled for
Open/Close reporting, and that Quick Arm reports as User 0. In order for Quick
Arm reports to be sent for all partitions, User #02 must have authority and
Open/Close enabled for all partitions. If a code with access to all partitions is not
desired, it is suggested that user #02 be assigned authority level 5 in all
partitions, and that the code be kept secret. Authority level 5 cannot disarm the
system unless armed by that user.
• Can perform all normal system functions
• Can be used to assign up to 148 lower level codes, which can be used by other
users of the system.
• Cannot assign anybody a level of 0 or 1.
• May change his own code.
• Can add, delete, change manager or operator codes. Each user's code can be
individually eliminated or changed at any time.
• Open/close reporting of added users are same as that of the master or
manager adding the new user.
• Can perform all system functions (Arm, Disarm, Bypass, etc.) programmed by
Master.
• May add, delete or change other users of the system below this level (Manager
cannot assign anybody a level of 0, 1, or 2).
• May change his own code.
• Open/close reporting of added users will be same as his own (enabled or
disabled as assigned by installer or master).
-
If Open/Close reports are