Displaying End-To-End Monitor Pairs In A Real-Time Graph; Displaying End-To-End Monitor Pairs In A Historical Graph - Brocade Communications Systems Brocade BladeSystem 4/24 User Manual

Supporting dcfm 10.4.x
Hide thumbs Also See for Brocade BladeSystem 4/24:
Table of Contents

Advertisement

2. Select the fabric for which you want to configure end-to-end monitoring from the Fabric list.
3. Select an initiator port from the Select an initiator port table.
4. Select a target port from the Select a target port table.
5. Click the right arrow to move the selected initiator and target ports to the Monitored Pairs
6. Click Apply.

Displaying end-to-end monitor pairs in a real-time graph

To display an end-to-end monitor pair in a graph, complete the following steps.
1. Select Monitor > Performance > End-to-End Monitors.
2. Select one or more end-to-end monitor pairs you want to view from the Monitored Pairs table.
3. Click Real-Time Graph.

Displaying end-to-end monitor pairs in a historical graph

To display monitored pairs in a historical graph, data collection must be enabled for the selected
fabric or enabled SAN wide.
To display an end-to-end monitor pair in a graph, complete the following steps.
1. Select Monitor > Performance > End-to-End Monitors.
2. Select one or more end-to-end monitor pairs you want to view from the Monitored Pairs table.
3. Click Historical Graph.
DCFM Enterprise User Manual
53-1001775-01
table.
The system automatically determines the initiator SID and the target DID identifiers for the pair
and displays them in the Monitored Pairs table.
Once the end-to-end monitored pair is applied to the device, the Status column in the
Monitored Pairs table displays 'Enabled'.
NOTE
If the initiator or target port is part of a logical switch and you move it to another logical switch,
the end-to-end monitor fails.
Once you have created the end-to-end monitored pair, you can view both real-time and
historical performance data. For step-by-step instructions refer to
monitor pairs in a real-time graph"
historical graph"
on page 303.
The Set End-to-End Monitor dialog box displays.
You can select up to 32 monitored pairs.
The Real Time Performance Graphs dialog box displays.
The Set End-to-End Monitor dialog box displays.
You can select up to 100 monitored pairs.
The Historical Performance Graph dialog box displays.
Displaying end-to-end monitor pairs in a real-time graph
on page 303 or
"Displaying end-to-end monitor pairs in a
11
"Displaying end-to-end
303

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcfm enterprise

Table of Contents