Finding The Logical Switch From A Physical Chassis; Assigning Ports To A Logical Switch - Brocade Communications Systems Brocade BladeSystem 4/24 User Manual

Supporting dcfm 10.4.x
Hide thumbs Also See for Brocade BladeSystem 4/24:
Table of Contents

Advertisement

21

Assigning ports to a logical switch

Finding the logical switch from a physical chassis

The Management application enables you to locate the logical switch from the physical chassis.
To find the logical switch, right-click the physical chassis within the Chassis Group in the Product
List and select Logical Switches > Logical_Switch_Name.
The logical switch you selected is highlighted in the Product List and Connectivity Map.
Assigning ports to a logical switch
A port can be assigned to only one logical switch.
All ports are initially assigned to the default logical switch. When you create a logical switch, it has
no ports and you must explicitly assign ports to it.
When you assign a port to a logical switch, it is removed from the original logical switch and
assigned to the new logical switch.
1. Select a switch on the Product List or Connectivity Map and select Configure > Logical
2. Select the physical chassis from which you want to assign ports in the Chassis list.
3. Select the ports you want to include in the logical switch from the Ports table.
4. Right-click anywhere in the Existing Logical Switches table and select Table > Expand All.
5. Select the logical switch in the Existing Logical Switches table.
6. Click the right arrow button.
7.
8. Select the Re-Enable ports after moving them check box.
9. (Optional) Select the Unbind Port Addresses while moving them check box.
10. Click Start to send these changes to the affected chassis.
11. When the changes are complete, click Close.
596
Switches.
The Logical Switches dialog box displays.
The ports display in the selected logical switch node in the Existing Logical Switches table.
Click OK on the Logical Switches dialog box.
The Logical Switch Change Confirmation and Status dialog box displays with a list of all
changes you made in the Logical Switches dialog box.
NOTE
Ports are disabled before moving from one logical switch to another.
NOTE
Most changes to logical switches will disrupt data traffic in the fabric.
The status of each change is displayed in the Status column and Status area in the dialog box.
DCFM Enterprise User Manual
53-1001775-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcfm enterprise

Table of Contents