18

Resolving merge conflicts

Resolving merge conflicts
You can resolve the following types of switch configuration conflicts:
Note that not all tests support resolution. If a test supports resolution, the Description column
contains the text 'Resolvable'.
To resolve merge conflicts, complete the following steps.
1. Select the failed test where the Description column contains the text 'Resolvable'.
2. Click Resolve.
3. Click OK on the warning message.
4. Repeat
5. Perform
482
Domain ID
TOV
Buffer To Buffer Credit
Disable Device Probe
Route Priority Per Frame
Sequence Level Switching
Suppress Class F
Long Distance Setting
Data Field Size
VC Priority
A "The switches in fabric Name will be disabled prior to making the configuration change. The
switches will be reenabled after the configuration changes are applied. Please confirm to
proceed." warning message displays.
The values of the Fabric chosen on the Set up merge options screen are applied to all devices
in the second fabric. Once the settings are applied the test is run again and the merge results
are updated.
If the test passes, go to
step
If an error occurs, an error message displays. You must use Web Tools or the CLI to resolve this
conflict. Click OK on the error message and go to
If you are resolving a domain ID error, there may be multiple switches involved. If multiple
switches have the domain ID error, the Configure Domain IDs dialog box displays listing all
devices that have domain ID conflict.
a. Select the device you want to resolve the domain ID for in the Available Switches table and
click the right arrow button.
b. Select a new domain ID for the device from the Domain ID list.
c.
Repeat steps a and b for each device in the Available Switches table.
d. Click OK on the Configure Domain IDs dialog box.
step 1
through
step 3
step 11
through
step 14
page 480 to finish resolving a merge conflict.
4.
step
until all resolvable tests pass.
of the procedure
"Merging two cascaded FICON fabrics"
4.