# CONSRV Events Table

Event Reason Code
FRU Code/Event Type
504
DVP/LIM/HW
506
DVP/PORT
509
DVP/PORT
511
LIM/DVP
514
DVP/ LIM/PORT
517
LIM
530
LIM/DVP
536
LIM/DVP
604
SBAR/SWM/HW
607
SBAR/SWM/HW
610
SWM/INFO
622
SBAR/INFO
625
SBAR/INFO

# Thermal Event Reason Codes Table

Event Reason Code
FRU Code/Event Type
800
DVP/LIM/HW
801
DVP/LIM/HW
802
DVP/LIM/HW
805
SWM/SBAR/HW
806
SWM/SBAR/HW
807
SWM/SBAR/HW
810
CTP/HW
811
CTP/HW
812
CTP/HW
850
CTP/HW
DCFM Enterprise User Manual
53-1001775-01
Description
M-EOS: Port module failure.
Fibre Channel port failure
Fibre Channel path failure.
LIM SPP failure.
SFP/XFP optics failure.
LIM SPP Offline.
LIM Power-up diagnostic failure.
Internal Frame Error port anomaly - threshold exceeded.
M-EOS: SBAR module failure.
M-EOS: Switch contains no operational SBAR cards.
SWM BMAC Link Down.
SWM powered off
SWM NV RAM failure.
Description
High temperature warning.
Critically hot temperature warning.
M-EOS: Port card shutdown due to thermal violations.
High temperature warning.
Critically hot temperature warning.
M-EOS: SBAR module shutdown due to thermal violations.
High temperature warning.
Critically hot temperature warning.
CTP shutdown due to thermal violations.
System shutdown due to CTP thermal threshold violations.
# CONSRV Events Table
B
Severity
3
3
0
3
3
3
3
2
3
4
0
0
0
Severity
3
3
3
3
3
3
3