Perfttmon - Brocade Communications Systems Brocade 8/12c Command Reference Manual

Brocade fabric os command reference manual supporting fabric os v7.0.0 (april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

22

perfTTmon

perfTTmon
Installs the Top Talker monitor in the specified mode.
SYNOPSIS
perfttmon
Port Mode:
perfttmon --add egress | ingress [slot/]port
perfttmon --show [slot/]port
[number_of_flows] [wwn| pid]
perfttmon --delete [slot/]port
Fabric Mode:
perfttmon --add fabricmode
perfttmon --show dom domain id
[number_of_flows] [wwn| pid]
perfttmon --delete fabricmode
DESCRIPTION
Use this command to install the Top Talker monitor. The Top Talker feature provides real-time information
about the top 'n' bandwidth consuming flows from a set of a large number of flows passing through a
specific point in the network (after initial stabilization).
Top Talkers can display between 1 and 32 flows depending on hardware platform. The maximum flows
displayed are as follows:
32
16
Top Talker supports the following two modes, Port Mode and Fabric Mode:
NOTES
This command requires an Advanced Performance Monitor license.
Top Talkers are incompatible with Frame Redirection, and therefore this feature is not supported on the
Brocade Encryption switch for encrypted data traffic.
Top Talkers are not supported on embedded platforms.
Top Talkers are not supported on FCoE ports or ports configured as mirror ports. Top Talkers are not
supported on VE_Ports, EX_Ports, VEX_Ports.
582
For the Brocade 300, 5100, 5300, 6510, 8000 (FC Ports only) FC8-xx, and
FC16-xx port blades.
For the Brocade 5000.
In Port Mode, Top Talker is installed at the port level to measure the traffic flowing through the port
to different destinations. The output displays the data in a sorted order based on the data rate of
each flow.
In Fabric Mode, Top Talker measures the top "n" bandwidth using flows on a given switch. Top
Talker installs only on E_Ports and measures the data rate of all the possible flows in the fabric. Flow
is a pair of communicating FC addresses (SID and DID). Top Talkers in Fabric Mode and EE
monitors are mutually exclusive. EE monitors must be removed from all switches before enabling
fabric mode.
Fabric OS Command Reference
53-1001764-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents