fwSetToDefault

Returns Fabric Watch thresholds and alarm levels to default values.
SYNOPSIS
fwsettodefault
DESCRIPTION
Use this command to return Fabric Watch thresholds and alarm levels to defaults for all classes and
areas in Fabric Watch.
Fabric Watch uses two types of settings: factory default settings and user-defined custom settings.
The fwSetToDefault command reapplies the Fabric Watch default configuration for all classes and
areas. Use the advanced configuration option provided with the portThConfig, thConfig, and
sysMonitor commands to view and modify custom and default values for specified classes and areas in
Fabric Watch. For specific configuration procedures, refer to the Fabric Watch Administrator's Guide.
NOTES
This command requires a Fabric Watch license.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To return alarm levels to default values:
To view the current Fabric Watch configuration for the environment class:
Fabric OS Command Reference
53-1001764-01
Factory default settings are automatically enabled. These settings vary depending on hardware
platform and cannot be modified.
For some settings, you can create custom threshold configurations to suit your unique environment.
switch:admin> fwsettodefault
Committing configuration...done.
switch:admin> sysmonitor --show env
Class: ENV
Area
: TEMP
ThLevel : Def
ActLevel: Def
High
:
Custom:
TimeBase: None
Value
Trigger : Above Action: Raslog,SNMP
Trigger : Below Action: None
Default:
TimeBase: None
Value
Trigger : Above Action: Raslog,SNMP
Trigger : Below Action: Raslog,SNMP
Low:
Custom:
TimeBase: None
Value
Trigger : Above Action: None
Trigger : Below Action: Raslog,SNMP
Default:
TimeBase: None
: 90
: 65
:32
22