fwSetToCustom

Sets Fabric Watch thresholds and alarm levels to custom values.
SYNOPSIS
fwsettocustom
DESCRIPTION
Use this command to set threshold and alarm levels to custom values for all Fabric Watch classes and
areas.
Fabric Watch uses two types of settings: factory default settings and user-defined custom settings.
The fwSetToCustom command allows you to switch from default to custom settings. The command
assumes that a set of user-defined thresholds have been configured prior to executing the
fwSetToCustom command. If no user-defined settings exist, this command reapplies the default values.
Use the advanced configuration option provided with the portThConfig, thConfig, and sysMonitor
commands to view and modify custom and default values for specified classes and areas in Fabric
Watch. For specific configuration procedures, refer to the Fabric Watch Administrator's Guide.
NOTES
This command requires a Fabric Watch license.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To apply configured custom settings to all Fabric Watch classes and areas:
To view the current Fabric Watch configuration for the environment class:
Fabric OS Command Reference
53-1001764-01
Factory default settings are automatically enabled. These settings vary depending on hardware
platform, and cannot be modified.
For some Fabric Watch parameters, you can create custom configurations to suit your unique
environment.
switch:admin> fwsettocustom
Committing configuration...done.
switch:admin> sysmonitor --show env
Class: ENV
Area
: TEMP
ThLevel : Cust (Applied)
ActLevel: Cust (Applied)
High
:
Custom:
TimeBase: None
Value
Trigger : Above Action: Raslog,SNMP
Trigger : Below Action: None
Default:
TimeBase: None
Value
Trigger : Above Action: Raslog,SNMP
Trigger : Below Action: Raslog,SNMP
Low:
Custom:
TimeBase: None
Value
: 90
: 65
:32
22
fwSetToCustom
403