22

portCfgShow

portCfgShow
Displays port configuration settings.
SYNOPSIS
portcfgshow
portcfgshow [slot/]port
portcfgshow -i [ndex1[-index2] [...] [-f]]
portcfgshow -slot slot1[-slot2] [...]
portcfgshow option [slot/][ge_port] [arguments]
[optional_arguments]
DESCRIPTION
Use this command to display the current configuration of a port. The behavior of this command is
platform-specific; output varies depending on port type and platform, and not all options are supported on
all platforms.
Non-GbE port displays
When used without operands, this command displays port configuration settings for all ports on a switch,
except Gigabit Ethernet (GbE) ports.
Displays supported only on the Brocade 7800/FX8-24 and on the Brocade FR4-18i platforms
Use this command with optional arguments to display the following parameters configured for a GbE port
on the Brocade 7800/FX8-24 and on the Brocade FR4-18i platforms.
Displays supported only on the Brocade 7800/FX8-24 platforms
Non-GbE port displays
The following information is displayed when the command is issued for all ports, for a single port, or for
one or more port ranges specified by their port index numbers or slot numbers:
Area Number
Speed
Fill Word (On Active)
682
IP interfaces on the GbE port
Static routes on the IP interfaces
Address resolution protocol (ARP) entries
VLAN tag configuration
Fibre Channel over IP (FCIP) tunnel configuration settings
-
IPSec configuration
-
QoS mappings (Brocade FR4-18i only)
Port mode information (Brocade FR4-18i only)
Inband Management IP addresses and routes.
Displays the port area number. This field is displayed only when portCfgShow is
executed for a single port.
Displays Auto for auto speed negotiation mode, or a specific speed of 1, 2, 4, or 8
Gbps. This value is set by the portCfgSpeed command.
Displays the fill word setting that will take effect after the next time the port goes
offline and comes back Possible values are 0(Idle-Idle), 1(arbff-arbff), 2(Idle-arbff),
or 3(A-A then SW I-A).This parameter is set by the portcfgFillword command.
Fabric OS Command Reference