NPIV PP Limit
CSCTL mode
D_Port mode
Fault Delay
Compression
Encryption
FEC
When portCfgShow is issued for a single FCoE port, only the following fields are displayed: Area
Number, Speed Level, AL_PA Offset, RSCN Suppressed, and NPIV PP Limit. If the command is
issued without operands on a DCX with one or more FCOE10-24 blades, the port parameters that are
not valid on the FCoE ports are marked with a dash (-). Refer to the example section for an illustration.
You can identify a single port to be displayed by its port number or by its port index number. Port ranges
are supported with index numbers or by specifying a slot or a slot range. Use switchShow for a listing of
valid ports, slots, and port index numbers. When used without operands, this command displays all
persistently disabled ports on the switch.
Specifying multiple ports with the index (-i) or slot (-s) option is supported only if PortSwap is disabled.
They are not supported on GbE ports and configured F_Port trunks. Use the -i option without a port index
argument to display the portSwap status, or alternately use portSwapShow.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
The Fabric OS port configuration commands are not supported on FCoE ports.
OPERANDS
This command has the following operands:
slot
port
Fabric OS Command Reference
53-1001764-01
Displays the maximum number of allowed logins for the port. Displays the default
of 126 or the configured maximum. This parameter is set with the
portCfgNPIVPort --setloginlimit command.
Displays ON if CSCTL mode is enabled on the port. Displays (..) or OFF if the
feature is disabled. This parameter is set with the portCfgQos command.
Displays ON when the port is configured as a D_Port; otherwise displays (..) or
OFF. Refer to the portCfgDPort command for more information.
Displays the Fault delay value. Displays 0 if the value is R_A_TOV. This is the
default. Displays 1 if the value is 1.2 seconds. This value is set by the
portCfgFaultDelay command. valid for FC ports only.
Displays ON when compression is enabled on a port. Displays (..) or OFF when
the configuration is disabled. Compression is enabled by the portCfgCompress
command; it is disabled by default.
Displays ON when encryption is enabled on a port. Displays (..) or OFF when the
configuration is disabled. Encryption is enabled by the portCfgEncrypt
command; it is disabled by default.
Displays ON when Forward Error Correction (FEC) is enabled on a port and the
port is online. Displays (..) or OFF when the configuration is disabled. FEC is
enabled by the portCfgFec command; it is enabled by default.
For bladed systems only, specifies the slot number of the port to be configured,
followed by a slash (/).
Specifies the number of the port to be displayed, relative to its slot for bladed
systems. Use switchShow for a listing of valid port numbers.
22
portCfgShow
685