bufOpMode

Changes or displays the Buffer Optimized Mode.
SYNOPSIS
bufopmode --set slot [-f]
bufopmode --reset slot
bufopmode --show slot
bufopmode --showall
DESCRIPTION
Use this command to display or change the buffer optimized mode on a switch.
When buffer optimized mode is enabled on a slot, additional buffers are allocated on the internal ports.
Use this feature, if you have slow draining devices connected to the slot and there are no long distance
links or F_Port buffers configured on that slot.
You must power off the slot before changing the buffer optimized mode. Changes take effect immediately
after the slot is powered on
Enabling buffer optimized mode removes all long distance configurations or F_Port buffers on that slot.
You will be prompted if any F_Port buffers or long distance configurations are detected.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
This command is supported only on the Brocade FC8-16, FC8-32, and FC8-48 blades in a DCX or
DCX-4S chassis. An asterisk (*) next to the slot configuration status indicates an unsupported blade.
Refer to the example section for an illustration.
This command is not supported on Control Processor (CP) blades and core blades.
OPERANDS
This command has the following operands:
slot
--set
--reset
--show
--showall
EXAMPLES
To display the buffer optimized mode for all slots on a DCX with supported blades:
Fabric OS Command Reference
53-1001764-01
Specifies the slot number.
Enables buffer optimized mode on the specified slot. This commands prompts for
confirmation before removing any F_Port buffers or long distance configurations
on that slot. Use the -f option to execute this command without confirmation.
Clears buffer optimized mode on the specified slot.
Displays the current buffer optimized mode for the specified slot (On or Off).
Displays the current buffer optimized mode for all slots. An asterisk (*) next to the
slot configuration status indicates an unsupported blade.
switch:admin> bufopmode --showall
Slot 1: buffer optimized mode - Off
Slot 2: buffer optimized mode - Off
Slot 3: buffer optimized mode - Off
Slot 4: buffer optimized mode - Off
22