Switchstatusshow - Brocade Communications Systems Brocade 8/12c Command Reference Manual

Brocade fabric os command reference manual supporting fabric os v7.0.0 (april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

switchStatusShow

Displays overall switch status.
SYNOPSIS
switchstatusshow
DESCRIPTION
Use this command to display the overall status for a switch. In addition, users with a Fabric Watch license
are able to view a listing of unhealthy ports that includes the port index number, the port name, and the
port status.
This command displays the following information: the overall switch status, and the status of the following
contributors:
Status values are HEALTHY, MARGINAL, or DOWN, depending on whether thresholds established by
switchStatusPolicySet have been exceeded. The overall status is based on the most severe status of
all contributors.
Refer to switchStatusPolicySet for details on the calculation of contributors and overall switch status.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To display a switch health report on a Brocade 6510 with one faulty port:
Fabric OS Command Reference
53-1001764-01
Report Time
Switch Name
IP address
Switch State: HEALTHY, MARGINAL, or DOWN
Duration: hours and minutes (HH:MM) the switch has been in the current state
Power supplies
Temperatures
Fans
WWN servers (dual-CP systems only)
Standby CP (dual-CP systems only with HA enabled)
Blades (bladed systems only)
Flash
Marginal ports
Faulty ports
Error Ports
switch:user> switchstatusshow
Switch Health Report
Switch Name:
ras220
IP address:
10.20.10.220
SwitchState:
MARGINAL
Duration:
47:42
Power supplies monitor
Temperatures monitor
Fans monitor
Flash monitor
Report time: 03/12/2011 08:48:00 PM
HEALTHY
HEALTHY
HEALTHY
MARGINAL
22