Powerofflistset - Brocade Communications Systems Brocade 8/12c Command Reference Manual

Brocade fabric os command reference manual supporting fabric os v7.0.0 (april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

22

powerOffListSet

powerOffListSet
Sets the order in which slots are powered off.
SYNOPSIS
powerofflistset
DESCRIPTION
Use this command to Modify the order in which slots are powered off. This command displays the current
order, and then prompts you interactively to confirm or modify the power-off position for each slot.
Whenever a power supply goes out of service or a field-replaceable unit (FRU) RU is inserted, the
system's available power is compared to the system's required power to determine if there is enough
power to operate. If less than the required power is available, the power-off list is processed, until there is
sufficient power for the system to operate.
If the system's power supply drops abruptly to insufficient levels, the power-off list cannot be processed.
The sudden lack of power causes the CP board processors to cease executing the firmware.
For example, if only one power supply is available to power a fully loaded system and the power supply
is removed from the chassis, all system operations terminate immediately, and the power-off list cannot
be processed. However, if the system is running on two power supplies (this is not recommended) and
one goes into a predicted fail state (in which the power supply is still supplying power), the power-off list
is processed as described.
The power-off list does not affect the order, in which slots are powered on. On power-on or when an
additional power supply is added, slots are processed sequentially, starting at slot 1.
NOTES
CP blade slots are not included in the power-off list.
Command output may vary depending on the hardware platform.
.Some FRUs may use significant power, but cannot be powered off by the software. For example a
missing blower FRU may change the power computation enough to affect how many slot blades can be
powered up.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To modify the power-off list order:
854
switch:admin> powerofflistset
Slot
Current POL
-------------------
10
1st
9
2nd
8
3rd
7
4th
4
5th
3
6th
2
7th
1
8th
1st slot to be powered off: (1..10) [10] 1
2nd slot to be powered off: (2..10) [9] 2
3rd slot to be powered off: (3..10) [8] 3
4th slot to be powered off: (4..10) [7] 4
5th slot to be powered off: (7..10) [7] 10