3. Hardware Installation
System Installation
5.
6.
7.
8.
74
As required, ensure that your system interconnection charts are handy. Refer to
the "
Connection Charts
" section on page 56 for details on completing the charts.
Ethernet Connections — a completely "local" network connection is
recommended, without IP connections to the outside world.
a.
Using an Ethernet cable, connect the ScreenPRO-II Controller's
Ethernet port to a Hub or Switch.
b.
Connect all ScreenPRO-II units to the Ethernet Hub or Switch.
c.
If your system uses BlendPRO-II, connect the BlendPRO-II chassis to
the Ethernet Hub or Switch.
d.
Connect all routers (such as MatrixPRO) to the Ethernet Hub or Switch.
Serial Connections — the ScreenPRO-II Controller's serial port is configured as
DCE, 115K baud, 8 data bits, 1 stop bit, no parity bits.
e.
For a single serial controlled router, use an RS-232 cable to connect the
router to the ScreenPRO-II Controller's EXT COMM port.
f.
To connect two (or more) serial routers, a third-party Ethernet-to-Serial
converter box is required, such as the Lantronix model UDS200 Device
Server (
http://www.lantronix.com/pdf/UDS200_PB.pdf
Lantronix UDS200 can control two serial routers.
Using RS-232 cables, connect each router to the UDS200 .
Set up a static IP address on the Lantronix device itself. The
recommended range is 192.168.0.200 - 192.168.0.239 — such
as not to conflict with other devices. Refer to the Lantronix
UDS200 User's Guide for instructions.
Using an Ethernet cable, connect the UDS200 to the same LAN
that includes the ScreenPRO-II Controller.
Note
The ScreenPRO-II Controller supports Lantronix models
UDS100 and UDS200 . In Chapter 4, refer to the "
Setup Menu
about Lantronix setup.
Source Connections
a.
If you are using external routing:
Ensure that all sources are properly connected to your analog
and digital routers.
Connect analog router outputs to analog inputs 1 and 2 on each
ScreenPRO-II. These are the default analog router inputs.
Connect digital router outputs to SDI inputs 1 and 2 on each
ScreenPRO-II.
b.
If you are using internal routing:
As required, connect discreet analog source outputs to the
desired analog inputs on each ScreenPRO-II.
As required, connect discreet digital source outputs to the
desired digital inputs on each ScreenPRO-II.
If analog DAs are utilized (recommended), connect analog
source outputs to DA inputs, and DA outputs to the desired
analog inputs on each ScreenPRO-II.
" section on page 131 for addition information