Downloading The Software Images Using Kermit (Pc Procedure) - Cisco WS-C6506 Software Manual

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 27
Working with System Software Images

Downloading the Software Images Using Kermit (PC Procedure)

Note
This procedure applies to the PC serial downloads only. For information on performing a serial download
on a UNIX workstation, see the
section on page
To perform a serial download of a software image over the supervisor engine console port, perform these
steps:
Copy the software image file to the directory where Kermit is loaded.
Step 1
Start Kermit on the PC.
Step 2
Note
At the Kermit> prompt, enter the connect command to connect to the switch. If your line and speed are
Step 3
set correctly, the switch Console> prompt appears.
Step 4
Enter the enable command to enter privileged mode.
Step 5
Enter the download serial command. The file is downloaded to module 1 by default.
When prompted, confirm the download.
Step 6
Enter the escape sequence Ctrl-]-c by holding down the Ctrl key while you press ], and then press c.
Step 7
At the Kermit> prompt, enter the send filename command to send the file to the switch.
Step 8
The switch downloads the image file, erases the flash memory on the supervisor engine or the
appropriate module, and reprograms the flash memory with the downloaded flash code.
Note
When the Kermit> prompt reappears, enter the connect command to return to the switch Console>
Step 9
prompt. You will see the status information as the switch erases and reprograms the flash memory.
Note
Step 10
Reset the switch using the reset system command.
When the switch reboots, enter the show version [mod] command to check the version of the code on
Step 11
the switch.
For an example that shows a complete serial download procedure using Kermit on a PC, see the
Note
Serial Download Procedure Example" section on page
OL-8978-04
"Downloading the Software Images Using Kermit (UNIX Procedure)"
27-30.
Before continuing, ensure that the line speed is correct and that you have selected the proper
serial line, as described in the
page
27-28.
The switch remains operational while the image downloads.
If you enter the connect command more than 2 minutes after the Kermit> prompt reappears, you
might see only a Console> prompt instead of the status information about erasing and
programming flash code.
Downloading the Software Images Over a Serial Connection on the Console Port
"Preparing to Download an Image Using Kermit" section on
27-31.
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
"PC
27-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents