Cisco WS-C6506 Software Manual page 598

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Using System Warnings on Port Counters
Console> (enable)
A sample syslog message is as follows:
1999 Nov 23 16:32:21 PDT -07:00 %SYS-3-SYS_MEMERR: Out of range while freeing address
0xabcdefab
NVRAM Logs
The syslog errors are generated for each configuration-related NVRAM log event. These events may
indicate configuration or hardware errors or NVRAM configurations that are made without notification
of users.The hardware errors NVRAM log is not syslogged. The NVRAM log time stamp is not included
in the message.
A sample syslog message is as follows:
1999 Nov 23 16:37:21 PDT -07:00 %SYS-4-SYS_NVLOG: convert_post_SAC_CiscoMIB:Block 63
converted from version 0 to 1
1999 Nov 23 16:37:25 PDT -07:00 %SYS-4-SYS_NVLOG: StartupConfig:Auto config started
Inband Errors
The inband syslog messages are generated when transmit or receive errors are detected. By default, the
inband syslog messages are enabled. This example shows how to enable inband error detection:
Console> (enable) set errordetection inband
Usage: set errordetection inband <enable|disable>
Conosle> (enable) set errordetection inband enable
Inband errordetection enabled.
When the resource errors on the receive side reach a multiple of 500, this syslog error is generated:
2000 Jun 24 06:37:25 PDT -07:00 %SYS-3-INBAND_NORESOURCE: inband resource error warning
(500)
2000 Jun 24 08:12:03 PDT -07:00 %SYS-3-INBAND_NORESOURCE: inband resource error warning
(1000)
For each spurious interrupt, a message similar to the following is logged:
1999 Dec 25 18:22:08 PDT -07:00 %SYS-3-INBAND_SPRINTR: inband spurious interrupt occurred
(2)
For each inband port transmit and receive failure, a message similar to the following is logged:
The number in parentheses indicates the number of times that the inband port is reset instead of the
Note
number of transmit or receive fails.
1999 Dec 25 18:22:08 PDT -07:00 %SYS-3-INBAND_TXRXFAIL: inband driver stuck/reset (2)
UDP Errors
When you enter the show netstat udp command, each socket overflow generates a message similar to
the following:
1999 Oct 31 23:59:59 PDT -07:00 %IP-3-UDP_SOCKOVFL: UDP socket overflow
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
20-22
Chapter 20
Checking Status and Connectivity
OL-8978-04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents