Cisco WS-C6506 Software Manual page 745

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 23
Configuring Redundancy
Send a Break signal to get into the problematic MSFC's ROMMON (the break will work if the MSFC is
Step 2
continually rebooting). You need to time the break so that it is issued after the system bootstrap message,
but before the main Cisco IOS image is decompressed (see the two arrows in the following display
output):
System Bootstrap, Version 12.0(3)XE, RELEASE SOFTWARE
Copyright (c) 1998 by cisco Systems, Inc.
Cat6k-MSFC platform with 131072 Kbytes of main memory <======= ISSUE BREAK AFTER THIS
POINT
Self decompressing the image :
######################################################################################
[OK]
<==========BUT BEFORE THIS POINT
Self decompressing the image :
##########################################################################################
##########################################################################################
##########################################################################################
##########################################################################################
##########################################################################################
##########################################################################################
##########################################################################################
##########################################################################################
### [OK]
At the ROMMON prompt, enter the confreg command:
Step 3
Enter y at the "do you wish to change the configuration? y/n [n]:" prompt.
a.
Press Enter to accept the default for all questions until you reach this prompt: "change the boot
b.
characteristics? y/n [n]:"
Enter y.
c.
Enter 0 to select the "0 = ROM Monitor" option at the next prompt.
d.
Review the Configuration Summary to ensure the following value: boot: the ROM Monitor.
e.
f.
You are again prompted with: "do you wish to change the configuration? y/n [n]:"
Enter n.
g.
You are returned to the ROMMON prompt.
h.
Enter the reset command and verify that the MSFC boots into ROMMON. This step ensures that this
Step 4
MSFC and the active MSFC will not boot concurrently.
Press Ctrl-C three times to return to the supervisor engine prompt.
Step 5
Ensure that high availability has synchronized the supervisor engine state by entering the show system
Step 6
highavailability command and verifying that high availability "Operational-status" is ON.
Enter the switch supervisor command.
Step 7
Enter the switch console command.
Step 8
OL-8978-04
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
MSFC Redundancy
23-53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents