Cisco WS-C6506 Software Manual page 597

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 20
Checking Status and Connectivity
Console> (enable)
Some sample syslog messages are as follows:
2000 Jan 11 06:00:27 PST -07:00 %SYS-4-SYS_HITRFC: 62% traffic detected on switching bus
(A)
2000 Feb 21 12:00:27 PST -07:00 %SYS-4-SYS_HITRFC: 65% traffic detected on switching bus
Low Remaining Memory
When memory allocation of clusters and buffers on the Catalyst 6500 series switch goes above a high
watermark of 90 percent, the syslog messages are generated. These actions generate the syslog
messages:
A sample syslog message is as follows:
1999 Sep 9 00:00:00 PDT -07:00 %SYS-3-SYS_MEMLOW: Memory cluster usage exceeded 90%
1999 Sep 9 00:00:00 PDT -07:00 %SYS-3-SYS_MEMLOW: Mbuf usage exceeded 90%
1999 Sep 9 00:00:00 PDT -07:00 %SYS-3-SYS_MEMLOW: Malloc usage exceeded 90%
Detected Memory Corruption
By default, memory corruption that is detected by the Memory Management Module (MMU) is enabled.
This example shows how to enable memory corruption detection:
Console> (enable) set errordetection memory
Usage: set errordetection memory <enable|disable>
Console> (enable) set errordetection memory enable
Memory error detection enabled.
Console> (enable) show errordetection
Inband error detection:
Memory error detection:
Packet buffer error detection:
Port counter error detection:
Port link-errors action:
Port link-errors interval:
Port link-errors high rx-threshold: 1000 packets
Port link-errors low rx-threshold:
Port link-errors high tx-threshold: 1000 packets
Port link-errors low tx-threshold:
Port link-errors sampling:
OL-8978-04
6
0%
0%
7
0%
0%
8
0%
0%
9
0%
0%
10
0%
0%
11
0%
0%
12
0%
0%
13
0%
0%
14
0%
0%
15
0%
0%
16
0%
0%
17
0%
0%
When cluster allocation usage goes above a high watermark of 90 percent, the throttle interval is
1 hour.
When mbufs allocation usage goes above a high watermark of 90 percent, the throttle interval is
1 hour.
When malloc allocation usage goes above a high watermark of 90 percent, the throttle interval is
1 hour.
disabled
enabled
errdisable
disabled
port-failover
30 seconds
1000 packets
1000 packets
3
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
Using System Warnings on Port Counters
20-21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents