Cisco WS-C6506 Software Manual page 733

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 23
Configuring Redundancy
Scenario 2: Disabling Configuration Synchronization on the Designated MSFC
In this scenario, the configuration synchronization is enabled. These examples show how to disable the
configuration synchronization:
Router-16# configure terminal
Enter configuration commands, one per line.
Router2(config)# redundancy
Router2(config-r)# high-availability
Router2(config-r-ha)# no config-sync
When the configuration synchronization is disabled, the following message is displayed on the
nondesignated MSFC:
00:13:00: %RUNCFGSYNC-6-SYNCEVENT:
The High-Availability Redundancy Feature is now disabled
The config mode is now accessible
Configuration mode is available on the CLI of the designated and nondesignated MSFC.
Scenario 3: Designated MSFC Comes Up
In this scenario, Config Sync AdminStatus is enabled. The designated MSFC validates the alternate
configuration, allowing the configuration synchronization to occur when the nondesignated MSFC
comes up.
Because the nondesignated MSFC is not up yet, Config Sync RuntimeStatus is disabled, and there is no
configuration synchronization. See the
page 23-41
This example shows that Router-16 is the designated MSFC, Config Sync AdminStatus is enabled, and
Config Sync RuntimeStatus is disabled:
Router-16# show redundancy
Designated Router: 1 Non-designated Router:0
Redundancy Status: designated
Config Sync AdminStatus
Config Sync RuntimeStatus: disabled
Scenario 4: Nondesignated MSFC Comes Up
Config Sync AdminStatus is Enabled
In this scenario, the nondesignated MSFC notifies the designated MSFC that it is up and Config Sync
AdminStatus is enabled. The designated MSFC requests the nondesignated MSFC to enable Config Sync
RuntimeStatus. The nondesignated MSFC enables Config Sync RuntimeStatus.
This message is displayed on the nondesignated MSFC:
00:00:07: %RUNCFGSYNC-6-SYNCEVENT:
The High-Availability Redundancy Feature is enabled
The config mode is no longer accessible
00:00:51: %RUNCFGSYNC-6-SYNCEVENT:
Non-Designated Router is now online
Running Configuration Synchronization will begin in 1 minute
OL-8978-04
for information on the nondesignated MSFC.
: enabled
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
End with CNTL/Z.
"Scenario 4: Nondesignated MSFC Comes Up" section on
MSFC Redundancy
23-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents