Cisco WS-C6506 Software Manual page 629

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 20
Checking Status and Connectivity
This example shows how to clear the maintenance association, customerXYA in customerXYADomain:
Console> (enable) clear ethernet-cfm maintenance-association ma-name-fmt text customerXYA
domain customerXYADomain
Maintenance Association customerXYA cleared from domain customerXYADomain.
Console> (enable)
Clearing a Metro Ethernet CFM Maintenance Point
To clear the Maintenance End Points (MEPs) or Maintenance Intermediate Points (MIPs) for a specific port,
perform one of these tasks in priviledged mode:
Task
Clear the CFM configured on a specific
module/port.
Clear the MEP configuration at a maintenance
level and clear the specified VLAN on a specific
port.
Note
Note
Clear the MIP configuration.
This example shows how to clear the MEP configuration for module 2, port 1 for a particular domain
customerxyz and VLAN 10:
Console> (enable) clear port ethernet-cfm 2/1 mep domain customerxyz vlan 10.
MEP config on Port 2/1 is cleared.
Console> (enable)
This example shows how to clear the MIP configuration for module 2, port 1:
Console> (enable) clear port ethernet-cfm 2/1 mip
MIP config on Port 6/1 is cleared.
Console> (enable)
Clearing the MAC Configuration for Maintenance End Points
To clear the port MAC configuration for Maintenance End Points (MEPs) that are down in a particular
module and port number of a VLAN, perform one of these tasks in priviledged mode:
Task
Clear the MAC configuration.
Clear the MAC configuration for MEPs in a
specific module and port number of a VLAN.
This example shows how to clear the port MAC configuration for MEPs that are down in module 3, port
14, and VLAN ID 10:
Console> (enable) clear ethernet-cfm port-mac-enable 3/14 vlan 10
OL-8978-04
MEP level values range from 0 to 7.
VLAN values range from 1 to 4094.
Configuring Metro Ethernet Connectivity Fault Management
Command
clear port ethernet-cfm mod/port
clear port ethernet-cfm mod/port mep [domain
domain-name | vlan vlan]
clear port ethernet-cfm mod/port mip [level
level vlan vlans]
Command
clear ethernet-cfm port-mac-enable
clear ethernet-cfm port-mac-enable mNo/pNo
vlan vlans
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
20-53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents