Cisco WS-C6506 Software Manual page 1179

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 49
Configuring SPAN, RSPAN and the Mini Protocol Analyzer
Adding the RSPAN Source Ports in Intermediate Switches
This example shows how to add the RSPAN source ports in the intermediate switches.
an RSPAN configuration; see
in Switch C can be configured for the same RSPAN session.
Figure 49-4
Switch A
Table 49-4
Adding the RSPAN Source Ports in Intermediate Switches
Switch
Ports
A (source)
4/1, 4/2
B (source)
3/1, 3/2, 3/3
C (intermediate)
C (source)
2/1, 2/2
D (destination)
1/2
Configuring Multiple RSPAN Sessions
This example shows how to configure multiple RSPAN sessions.
configuration; see
example is a typical scenario where the monitoring probes would be placed in the data center and the
source ports in the access switches (other ports in any of the switches can also be configured for
RSPAN). If there is no change in the route for the SPAN traffic, the destination switch and the
intermediate switches need to be configured only once.
In
Figure
probe 2). The direction of traffic over trunks T1 through T6 is shown only for understanding; the
direction of the trunks depends on the STP states of the trunks for the RSPAN VLAN(s). You need to
configure the RSPAN VLANs in each of the switches for the RSPAN sessions. With VTP enabled in the
network, you can create the RSPAN VLAN in one switch and VTP propagates it to the other switches in
that VTP domain. With VTP disabled, create the RSPAN VLANs in each switch.
OL-8978-04
Table 49-4
Adding the RSPAN Source Ports in Intermediate Switches
Switch D
1/1
T1
1/2
Switch C
3/1 2/1 2/2 3/2
T2
1/2
4/1 4/2
3/1 3/2
RSPAN VLAN
901
901
901
901
901
Table 49-5
for the configuration commands to configure this RSPAN session. This
49-5, two RSPAN sessions are used with RSPAN VLANs 901 (for probe 1) and 902 (for
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
for the commands to configure this RSPAN session. Ports 2/1-2
Destination switch
(data center)
1/2
Probe
Intermediate switch
(distribution)
T3
1/1
Source switch(es)
Switch B
(access)
3/3
Direction
RSPAN CLI Commands
Ingress
set rspan source 4/1-2 901 rx
Bidirectional
set rspan source 3/1-3 901
No RSPAN CLI command needed
Bidirectional
set rspan source 2/1-2 901
set rspan destination 1/2 901
Configuring RSPAN on the Switch
Figure 49-4
Figure 49-5
shows an RSPAN
shows
49-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents