Cisco WS-C6506 Software Manual page 1098

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Configuring Network Admission Control with LAN Port IP
Setting EAPOUDP-Related Timers
To set EAPOUDP-related timers, perform this task in privileged mode:
Task
Set EAPOUDP-related timers.
The timer defaults and ranges are as follows:
This example shows how to set the revalidation timer to 200 seconds:
Console> (enable) set eou timeout revalidation 200
Console> (enable)
Setting EOU Rate Limiting
To set EOU rate limiting (the default is 0 and the range is 10 through 200), perform this task in privileged
mode:
Note
The default rate limit value of 0 disables rate limiting. With rate limiting disabled, there is no limit on
simultaneous LAN port IP authentication sessions.
Task
Set EOU rate limiting.
This example shows how to set EOU rate limiting to 40:
Console> (enable) set eou rate-limit 40
eou ratelimit set to 40.
Console> (enable)
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
44-14
aaa—The default is 60 seconds; the range is 1 through 60 seconds.
hold-period—The default is 180 seconds; the range is 60 through 86400 seconds.
retransmit—The default is 3 seconds; the range is 1 through 60 seconds.
revalidation—The default is 36000 seconds; the range is 5 through 86400 seconds.
status-query—The default is 300 seconds; the range is 30 through 1800 seconds.
Chapter 44
Configuring Network Admission Control
Command
set eou timeout aaa aaa-timeout
set eou timeout hold-period hold-timeout
set eou timeout retransmit retransmit-timeout
set eou timeout revalidation revalidation-timeout
set eou timeout status-query status-query-timeout
Command
set eou rate-limit ratelimit
OL-8978-04