Cisco WS-C6506 Software Manual page 1157

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 47
Configuring SNMP
This example shows how to verify the SNMPv3 setup for guestuser1 from a workstation:
workstation% getnext -v3 10.6.4.201 guestuser1 ifDescr.0
Enter Authentication password :guestuser1password
Enter Privacy password
ifDescr.1 = sc0
This example shows how to verify the SNMPv3 setup for guestgroup in the snmpEngineID MIB from a
workstation:
workstation% getnext -v3 10.6.4.201 guestuser1 snmpEngineID
Enter Authentication password :guestuser1pasword
Enter Privacy password
snmpEngineID = END_OF_MIB_VIEW_EXCEPTION
This example shows how to verify the SNMPv2c setup for public access from a workstation:
workstation% getnext -v2c 10.6.4.201 public snmpEngineID
snmpEngineID.0 =
00 00
These examples show how to increase guestgroup's access right to read privileges for
snmpEngineMibView:
Console> (enable) set snmp view snmpEngineMibView 1.3.6.1.6.3.10.2.1 included
Snmp view name was set to snmpEngineMibView with subtree 1.3.6.1.6.3.10.2.1 included,
nonvolatile
Console> (enable) set snmp access guestgroup security-model v3 authentication read
snmpEngineMibView
Snmp access group was set to guestgroup version v3 level authentication,
readview snmpEngineMibView, nonvolatile.
This example shows how to verify the SNMPv3 access for guestuser1 from a workstation:
workstation% getnext -v3 10.6.4.201 guestuser1 snmpEngineID
Enter Authentication password :guestuser1password
Enter Privacy password
snmpEngineID.0 =
00 00
This example shows how to remove the access for guestgroup:
Console> (enable) clear snmp acc guestgroup security-model v3 authentication
Cleared snmp access guestgroup version v3 level authentication.
This example shows how to verify that the access for guestuser1 has been removed from a workstation:
workstation% getnext -v3 10.6.4.201 guestuser1 ifDescr.1
Enter Authentication password :guestuser1password
Enter Privacy password
Error code set in packet - AUTHORIZATION_ERROR:1.
This example shows how to verify the access for guestuser2 from a workstation:
workstation% getnext -v3 10.6.4.201 guestuser2 ifDescr.1
Enter Authentication password :guestuser2password
Enter Privacy password
REPORT received, cannot recover:
usmStatsUnsupportedSecLevels.0 = 1
OL-8978-04
00 09
00 10
7b f2
00 09
00 10
7b f2
:privacypasswd1
:privacypasswd1
82 00
00 00
:privacypasswd1
82 00
00 00
:privacypasswd1
:privacypasswd2
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
Configuring SNMPv3 on the Switch
47-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents