AT&T MERLIN LEGEND Release 4.0 Feature Reference page 501

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 4.0:
Table of Contents

Advertisement

Feature Reference
Station Message
Detail Recording
(SMDR)
continued
System Numbering
Beginning with Release 3.0, if the caller provides an invalid or
incomplete barrier code for three attempts, either
are recorded in the ACCOUNT field. If the connection is broken before
the third attempt, the ACCOUNT field contains
hangs up after the third attempt, but before receiving reorder tone, the
ACCOUNT field may contain either
hangs up after the third attempt and after receiving reorder tone, the
ACCOUNT field contains 16 zeros.
If the caller uses Remote Access to dial out on a line or trunk, the STN
field is blank on the first SMDR record and a second record is
generated for the outgoing call.
If the system includes DID or dial-in tie trunks. the number assigned to
the trunk can be programmed for Remote Access. This allows remote
access users to call in on the DID or dial-in trunk.
The remote access code can be renumbered. The factory-set remote
access code is 889.
999999
. If the caller
999999
or 16 zeros. If the caller
999999
Remote Access
or 16 zeros
501

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend 3.1

Table of Contents