DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
Parameters
None.
Restrictions
None.
Example
To display the standalone device environment:
DWS-3160-24PC:admin#show environment
Command: show environment
Internal Power
External Power
Right Fan 1
Right Fan 2
Right Fan 3
Right Fan 4
Current Temperature(Celsius) :
Fan High Temperature Threshold(Celsius)
Fan Low Temperature Threshold(Celsius)
High Warning Temperature Threshold(Celsius) :
Low Warning Temperature Threshold(Celsius)
DWS-3160-24PC:admin#
52-3
config temperature threshold
Description
This command is used to configure the warning threshold for high and low temperature. When the
temperature is above the high threshold limit or below the low threshold limit, the Switch will send
out alarm traps or automatically shut the Switch system down.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
Parameters
threshold - Specifies the high and low threshold value.
high - (Optional) Specifies to configure the high threshold value. The high threshold must
bigger than the low threshold.
<temperature -500-500> - Enter the high threshold temperature here. This value must be
between -500 and 500.
low - (Optional) Specifies to configure the low threshold value.
<temperature -500-500> - Enter the low threshold temperature here. This value must be
between -500 and 500.
: Active
: Fail
: Speed Low
(3000 RPM)
: Speed Low
(3000 RPM)
: Speed Low
(3000 RPM)
: Speed Low
(3000 RPM)
30
518
:
40
:
35
79
:
11