Config Temperature Threshold - D-Link DGS-3000 Series Reference Manual

Layer 2 managed gigabit switch
Hide thumbs Also See for DGS-3000 Series:
Table of Contents

Advertisement

DGS-3000 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
Format
show environment
Parameters
None.
Restrictions
None.
Example
To display the device environment:
DGS-3000-26TC:admin#show environment
Command: show environment
Temperature Trap State
Temperature Log State
Internal Power
External Power
Current Temperature(Celsius) :
High Warning Temperature Threshold(Celsius) :
Low Warning Temperature Threshold(Celsius)
DGS-3000-26TC:admin#
55-3

config temperature threshold

Description
This command is used to configure the warning threshold for high and low temperature.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
Parameters
high - (Optional) Specifies to configure high threshold value. The high threshold must bigger than
the low threshold.
<temperature -500-500> - Enter the high threshold temperature.
low - (Optional) Specifies to configure low threshold value.
<temperature -500-500> - Enter the low threshold temperature.
Restrictions
Only Administrators and Operators can issue this command.
: Enabled
: Enabled
: Active
: None
32
513
79
:
11

Advertisement

Table of Contents
loading

Table of Contents