Example
To configure time zone:
DWS-3160-24PC:admin#config time_zone operator + hour 8 min 00
Command: config time_zone operator + hour 8 min 0
Success.
DWS-3160-24PC:admin#
73-7

config dst

Description
This command is used to configure the Daylight Saving Time (DST) of the Switch.
Format
config dst [disable | repeating {s_week <start_week 1-4,last> | s_day <start_day sun-sat> |
s_mth <start_mth 1-12> | s_time <start_time hh:mm> | e_week <end_week 1-4,last> | e_day
<end_day sun-sat> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> | offset [30 | 60 | 90
| 120]} | annual {s_date <start_date 1-31> | s_mth <start_mth 1-12> | s_time <start_time
hh:mm> | e_date <end_date 1-31> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> |
offset [30 | 60 | 90 | 120]}]
Parameters
disable - Disable the Daylight Saving Time of the Switch.
repeating - Set the Daylight Saving Time to repeating mode.
s_week, e_week - (Optional) Configure the start /end week number of Daylight Saving Time.
<start_week 1-4, last> - Enter the starting week number of Daylight Saving Time here.
This value must be between 1 and 4.
<end_week 1-4, last> - Enter the ending week number of Daylight Saving Time here. This
value must be between 1 and 4.
s_day, e_day - (Optional) Configure the start /end day number of Daylight Saving Time.
<start_day sun-sat> - Enter the starting day value of Daylight Saving Time here. This
value must either be sun, mon, tue, wed, thu, fri or sat.
<end_day sun-sat> - Enter the ending day value of Daylight Saving Time here. This value
must either be sun, mon, tue, wed, thu, fri or sat.
s_mth, e_mth - (Optional) Configure the start /end month number of Daylight Saving Time.
<start_mth 1-12> - Enter the starting month number of Daylight Saving Time here. This
value must be between 1 and 12.
<end_mth 1-12> - Enter the ending month number of Daylight Saving Time here. This
value must be between 1 and 12.
s_time, e_time - (Optional) Configure the start /end time of Daylight Saving Time.
<start_time hh:mm> - Enter the starting time of Daylight Saving Time here. This value
must be in the hh:mm format.
<end_time hh:mm> - Enter the starting time of Daylight Saving Time here. This value
must be in the hh:mm format.
offset - (Optional) Indicates number of minutes to add or to subtract during summertime. The
ranges of offset are 30, 60, 90, and 120. The default value is 60.
30 - Specifies that the offset range will 30 minutes.
60 - Specifies that the offset range will 60 minutes.
90 - Specifies that the offset range will 90 minutes.
120 - Specifies that the offset range will 120 minutes.