Show Snmp Engineid - D-Link DWS-3160-24TC Cli Reference Manual

Gigabit ehernet unified switch
Hide thumbs Also See for DWS-3160-24TC:
Table of Contents

Advertisement

DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
Parameters
engineID - Identify for the SNMP engine on the Switch. It is octet string type. It accepts the hex
number directly.
<snmp_engineID 10-64> - Enter the SNMP engine ID here. This value must be between 10
and 64.
Restrictions
Only Administrators can issue this command.
Example
To configure SNMP engine ID to "1023457890":
DWS-3160-24PC:admin# config snmp engineID 1023457890
Command: config snmp engineID 1023457890
Success.
DWS-3160-24PC:admin#

66-18 show snmp engineID

Description
This command is used to display the identification of the SNMP engine on the Switch. The default
value is suggested in RFC2271. The very first bit is 1, and the first four octets are set to the binary
equivalent of the agent's SNMP management private enterprise number as assigned by IANA, D-
Link is 171. The fifth octet is 03 to indicate the rest is the MAC address of this device. The 6th –
11th octets is MAC address.
Format
show snmp engineID
Parameters
None.
Restrictions
None.
Example
To display the SNMP engine ID:
618