DGS-3120-24TC:admin#show environment
Command: show environment
High Warning Temperature Threshold(Celsius) :
Low Warning Temperature Threshold(Celsius)
Unit
1
Internal Power
External Power
Right Fan 1
Right Fan 2
Current Temperature(Celsius) :
Fan High Temperature Threshold(Celsius)
Fan Low Temperature Threshold(Celsius)
Unit
2
Internal Power
External Power
Right Fan 1
Right Fan 2
Current Temperature(Celsius) :
Fan High Temperature Threshold(Celsius)
Fan Low Temperature Threshold(Celsius)
Unit
3
Internal Power
External Power
Right Fan 1
Right Fan 2
Current Temperature(Celsius) :
Fan High Temperature Threshold(Celsius)
Fan Low Temperature Threshold(Celsius)
DGS-3120-24TC:admin#
72-3

config temperature threshold

Description
This command is used to configure the warning threshold for high and low temperature.
The temperature thresholds are dependent on product. When temperature is above high threshold
or below low threshold, SW will send alarm traps or shut down the Switch system.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
Parameters
threshold - Specify the high and low threshold value.
high - (Optional) To configure high threshold value. m is the high threshold value. The high
threshold must bigger than the low threshold.
: Active
: Fail
: Speed Low
(3000 RPM)
: Speed Low
(3000 RPM)
37
: Active
: Fail
: Speed Low
(3000 RPM)
: Speed Low
(3000 RPM)
38
: Active
: Fail
: Speed Low
(3000 RPM)
: Speed Low
(3000 RPM)
37
718
79
:
-10
:
40
:
35
:
40
:
35
:
40
:
35