<string 22> - Enter the maintenance domain name here. This name can be up to 22
characters long.
md_index - Specifies the maintenance domain index.
<uint 1-4294967295> - Enter the maintenance domain index value here. This value must be
between 1 and 4294967295.
mip - (Optional) This is the control creations of MIPs.
none - Do not create MIPs. This is the default value.
auto - MIPs can always be created on any ports in this MD, if that port is not configured with
an MEP of this MD. For the intermediate Switch in an MA, the setting must be automatic in
order for the MIPs to be created on this device.
explicit - MIPs can be created on any ports in this MD, only if the next existent lower level has
an MEP configured on that port, and that port is not configured with an MEP of this MD.
sender_id - (Optional) This is the control transmission of the sender ID TLV.
none - Do not transmit the sender ID TLV. This is the default value.
chassis - Transmit the sender ID TLV with the chassis ID information.
manage - Transmit the sender ID TLV with the managed address information.
chassis_manage - Transmit sender ID TLV with chassis ID information and manage address
information.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure the maintenance domain called "op_domain" and Specifies the explicit option for
creating MIPs:
DWS-3160-24PC:admin# config cfm md op_domain mip explicit
Command: config cfm md op_domain mip explicit
Success.
DWS-3160-24PC:admin#
19-3

create cfm ma

Description
This command is used to create a maintenance association. Different MAs in an MD must have
different MA Names. Different MAs in different MDs may have the same MA Name.
Format
create cfm ma <string 22> {ma_index <uint 1-4294967295>} md [<string 22> | md_index
<uint 1-4294967295>]
Parameters
ma - Specifies the maintenance association name.
<string 22> - Enter the maintenance association name here. This name can be up to 22
characters long.
ma_index - (Optional) Specifies the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value here. This value must
be between 1 and 4294967295.