Table 11-12: EmWeb Log Messages
Component
Message
EmWeb
EMWEB (Telnet): Max number of Telnet
login sessions exceeded
EmWeb
EMWEB (SSH): Max number of SSH login
sessions exceeded
EmWeb
Handle table overflow
EmWeb
ConnectionType EmWeb socket accept()
failed: errno
EmWeb
ewsNetHTTPReceive failure in
NetReceiveLoop() - closing connection.
EmWeb
EmWeb: connection allocation failed
EmWeb
EMWEB TransmitPending :
EWOULDBLOCK error sending data
EmWeb
ewaNetHTTPEnd: internal error - handle not
in Handle table
EmWeb
ewsNetHTTPReceive:recvBufCnt exceeds
MAX_QUEUED_RECV_BUFS!
EmWeb
EmWeb accept: XXXX
Table 11-13: CLI_UTIL Log Messages
Component
Message
CLI_UTIL
Telnet Send Failed errno = 0x%x
CLI_UTIL
osapiFsDir failed
Log Messages
Managed Switch CLI Manual, Release 8.0.3
Cause
A user attempted to connect via telnet when
the maximum number of telnet sessions
were already active.
A user attempted to connect via SSH when
the maximum number of SSH sessions were
already active.
All the available EmWeb connection handles
are being used and the connection could not
be made.
Socket accept failure for the specified
connection type.
Socket receive failure.
Memory allocation failure for the new
connection.
Socket error on send.
EmWeb handle index not valid.
The receive buffer limit has been reached.
Bad request or DoS attack.
Accept function for new SSH connection
failed. XXXX indicates the error info.
v1.0, July 2010
Cause
Failed to send text string to the
telnet client.
Failed to obtain the directory
information from a volume's
directory.
11-7